SKU 98464
For technical questions, please call 1-800-444-3353.
Page 13
nected and is incapable of firing any
Brads.
With the Driver Guide Cover (52A)
8.
facing away from you, push the Lock
Spring (92) and remove Driver Guide
Cover.
Remove the jammed Brad.
9.
Close the Driver Guide Cover (52A),
10.
making sure it locks in place.
Reload the Nailer with Brads. Then,
11.
reconnect the air supply hose to the
tool.
Press the Safety (50A) against a
12.
piece of scrap wood, and test fire the
Nailer several times while checking
for proper operation. If the Nailer is
properly firing, you may continue us-
ing the tool. If the tool fails to perform
properly, immediately discontinue use
and have the tool repaired by a quali-
fied service technician.
When finished working, disconnect
13.
the air supply. Remove the Brads.
Then, store the Nailer in a clean, dry,
safe location out of reach of children
.
TO PREVENT
SERIOuS INjuRY
FROm ACCIdENTAL
OPERATION:
Release trigger, detach the air
supply, and safely discharge
any residual air pressure in
the tool before performing any
inspection, maintenance, or
cleaning procedures.
TO PREVENT SERIOuS
INjuRY FROm TOOL
FAILuRE:
do not use damaged
equipment. If abnormal noise,
vibration, or any leakage is
detected, have the problem
corrected before further use.
Cleaning, maintenance, and
Lubrication
Anytime
any
maintenance or re-
pairs are done (including clear-
ing jams),
FIRST:
1.
Disconnect the Nailer/Stapler from the
air hose.
2. Empty Magazine completely.
3. Attempt to fire the Nailer/Stapler into a
piece of scrap wood to ensure that it is
disconnected and is incapable of firing
any staples.
4.
Always leave magazine open dur-
ing maintenance. The magazine
is spring-loaded and may cause
parts or a fastener to fly out of the
Nailer/Stapler.
Clearing jams for 97524 Nailer/Stapler
ALWAYS wear ANSI-
1.
approved impact safety goggles
when clearing jams.
Disconnect tool from air hose, empty
2.
Magazine A (67) of fasteners, release
any built-up air pressure, and leave
the magazine open, as explained
above.
2. While doing this step and the next 2
steps, hold the Nailer/Stapler pointed