Page 12
For technical questions, please call 1-800-444-3353.
SKU 92917
93253
7.
FIRMLY
press the Safety Nosepiece
against the workpiece and squeeze
the Trigger.
The tool must cycle
(fire) only once.
Release the Trigger
and squeeze it again.
The tool must
not cycle (fire)*.
With the Trigger
held, carefully lift the tool and press
it against the workpiece again.
The
tool must not cycle (fire).
If it fails
to perform in the manner explained in
bold, have it repaired by a qualified
service technician.
* If the nailer is allowed to rebound off the
workpiece it may cause the Safety Nosepiece
to extend enough to reset it and allow another
fastener to be fired.
Loading the Tool
TO PREVENT
SERIOUS INJURY
FROM ACCIDENTAL
OPERATION, BEFORE
LOADING:
• Wear ANSI-approved safety
goggles with side shields.
Other people in the work area
must also wear ANSI-approved
impact safety goggles with side
shields.
• Release the trigger.
• Detach the air supply.
• Attempt to fire the Tool into
a piece of scrap wood to
ensure that it is disconnected
and is incapable of firing any
fasteners.
1.
CANISTER
COVER (84)
CANISTER
(90)
DOOR
(53)
PIN
(91)
To open the Canister (90), press
down on the Pin (91) and swing the
Door (53) and Canister Cover (84)
open.
2. Check the Canister Platform (86)
inside the Canister (90). The
Platform can be adjusted up and
down to use various lengths of nails
from 3/4” to 1-3/4”:
A. 3/4” Long Nails
(Use top setting).
B. Between 3/4” and 1-3/4” Long Nails
(Use middle setting).
C. 1-3/4” Long Nails
(Use bottom setting).
REV 05k; 09h