background image

Page 2

For technical questions, please call 1-800-444-3353.

Item 69450 

        

table of Contents

Safety ......................................................... 2
Specifications ............................................. 6
Setup .......................................................... 7
Operation ................................................... 10

Maintenance .............................................. 11
Parts List and Diagram .............................. 14
Warranty .................................................... 15

WaRninG SYmBOlS anD DEFinitiOnS

This is the safety alert symbol.  It is used to alert you to potential personal injury hazards.  

Obey all safety messages that follow this symbol to avoid possible injury or death.

Indicates a hazardous situation which, if not avoided,  

will result in death or serious injury.

Indicates a hazardous situation which, if not avoided,  

could result in death or serious injury.

Indicates a hazardous situation which, if not avoided,  

could result in minor or moderate injury.

Addresses practices not related to personal injury.

Symbol

Property or statement

PSi

Pounds per square inch of pressure

CFm

Cubic Feet per Minute flow

SCFm

Cubic Feet per Minute flow 

at standard conditions

nPt

National pipe thread, tapered

nPS

National pipe thread, straight

WARNING marking concerning  

Risk of Eye Injury.  Wear ANSI-approved 

safety goggles with side shields.

Symbol

Property or statement

Warning marking concerning  

Risk of  Puncture Injury.  

Wear heavy-duty work gloves.

Read the manual before 

set-up and/or use.

WARNING marking concerning  

Risk of Hearing Loss.   

Wear hearing protection.
WARNING marking concerning  

Risk of Respiratory Injury.  Wear 

NIOSH-approved dust mask/respirator.

WARNING marking concerning 

Risk of Explosion.

table a:  Symbol Definitions

Sa
FE

tY

O

PER
ati

O

n

m

aint

Enan
CE

SE

tu

P

Summary of Contents for 69450

Page 1: ......

Page 2: ...could result in minor or moderate injury Addresses practices not related to personal injury Symbol Property or statement PSI Pounds per square inch of pressure CFM Cubic Feet per Minute flow SCFM Cubi...

Page 3: ...Do not use the tool while tired or under the influence of drugs alcohol or medication A moment of inattention while operating the tool increases the risk of injury to persons b Dress properly Do not w...

Page 4: ...ce that is capable of exceeding 200 PSI Over pressurizing the tool may cause bursting abnormal operation breakage of the tool or serious injury to persons Use only clean dry regulated compressed air a...

Page 5: ...t masks that are specially designed to filter out microscopic particles California Health Safety Code 25249 5 et seq WARNING The brass components of this product contain lead a chemical known to the S...

Page 6: ...9450 Functional Description Specifications Maximum Air Pressure 100 PSI Air Inlet 1 4 18 NPT Fastener Capacity Up to 3 1 2 Long 16d Air Consumption 1 CFM 90 PSI Components and Controls Air Inlet Guide...

Page 7: ...are not required WARNING To prevent serious injury from accidental operation Do not install a female quick coupler on the tool Such a coupler contains an air valve that will allow the air tool to ret...

Page 8: ...r Prevents dirt and condensation from damaging tool or workpiece C Regulator Adjusts air pressure to tool D Lubricator optional For air tool lubrication E Coupler and Plug Provides quick connection an...

Page 9: ...4 minimum recommended Distributes air to branch lines F Ball Valve To drain moisture from system G Branch Air Line 1 2 minimum recommended Brings air to point of use H Air Hose Connects air to tool I...

Page 10: ...est the tool as directed in the prior section 2 If an automatic oiler is not used add a few drops of Pneumatic Tool Oil to the airline connection before use Add a few drops more after each hour of con...

Page 11: ...inlet using only pneumatic tool oil Lubricate the internal mechanism using only white lithium grease Other lubricants may damage the mechanism and may be highly flammable causing an explosion Note The...

Page 12: ...air supply pressure PSI Tool cycles but nail is not driven Insufficient air flow Check for loose connections and make sure that air supply is providing enough air flow CFM and pressure PSI to the tool...

Page 13: ...duct In fact the manufacturer and or distributor expressly states that all repairs and parts replacements should be undertaken by certified and licensed technicians and not by the buyer The buyer assu...

Page 14: ...Guider 1 6 Slide Cover 1 7 O Ring 41 1 8 2 8 Seal Ring 1 9 Cylinder 1 10 O Ring 30 1 1 8 1 11 O Ring 30 2 5 1 Part Description Qty 12 Piston Assembly 1 13 Bumper 1 14 Body 1 15 Washer 1 16 Restrict B...

Page 15: ...the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you This warranty is expressly in lieu of all other warranties express or impl...

Page 16: ...3491 Mission Oaks Blvd PO Box 6009 Camarillo CA 93011 800 444 3353...

Reviews: