Central Pneumatic 68247 Owner'S Manual & Safety Instructions Download Page 2

Page 2

For technical questions, please call 1-888-866-5797.

Item 68247 

        

Sa
FE
ty

Op
E

ra
ti

O

n

Maint

E

nanc

E

in

S

talla

ti

O

n

table of contents

Safety ......................................................... 2
Installation .................................................. 4
Specifications ............................................. 4
Operation .................................................... 8

Maintenance ............................................... 8
Parts List and Diagram .............................. 10
Warranty .................................................... 12

 

 

 
 

WarninG SyMBOlS anD DEFinitiOnS

This is the safety alert symbol.  It is used to alert you to potential 

personal injury hazards.  Obey all safety messages that 

follow this symbol to avoid possible injury or death.

Indicates a hazardous situation which, if not avoided,  

will result in death or serious injury.

Indicates a hazardous situation which, if not avoided,  

could result in death or serious injury.

Indicates a hazardous situation which, if not avoided,  

could result in minor or moderate injury.

Addresses practices not related to personal injury.

iMpOrtant SaFEty inFOrMatiOn

General Safety Warnings

  WarninG read all safety warnings and instructions.   

Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury.   

Save all warnings and instructions for future reference.

The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible 
conditions and situations that may occur.  It must be understood by the operator that common sense 
and caution are factors which cannot be built into this product, but must be supplied by the operator.

1. 

Work area safety

a. 

Keep work area clean and well lit.

  

Cluttered or dark areas invite accidents.

b. 

Keep children and bystanders away 
from an operating regulator.

2. 

personal safety

a. 

Stay alert, watch what you are doing and 
use common sense when operating this 
regulator.  Do not use this regulator while 
you are tired or under the influence of 
drugs, alcohol or medication.

  A moment 

of inattention while operating a regulator 
may result in serious personal injury.

b. 

Use personal protective equipment.  
always wear anSi-approved eye 
protection during setup and use.

Summary of Contents for 68247

Page 1: ...ference 20k When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2020 by Harbor Freight Tools A...

Page 2: ...ty warnings and instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference The warning...

Page 3: ...tor Safety Warnings 1 risk of bursting do not adjust regulator higher than marked maximum pressure of attachment 2 risk of injury do not direct air stream at people or animals 3 Do not use to supply b...

Page 4: ...xt under subheadings therein before set up or use of this product note For additional information regarding the parts listed in the following pages refer to the Assembly Diagram near the end of this m...

Page 5: ...zed air supply components The air hose must be long enough to reach the work area with enough extra length to allow free movement while working 4 Check that the regulator handle is loose 5 Close the i...

Page 6: ...A Air Hose Connects air to tool B Filter Prevents dirt and condensation from damaging tool or workpiece C Regulator Adjusts air pressure to tool D Lubricator optional For air tool lubrication E Couple...

Page 7: ...r vibration reduction E Main Air Line 3 4 minimum recommended Distributes air to branch lines F Ball Valve To drain moisture from system G Branch Air Line 1 2 minimum recommended Brings air to point o...

Page 8: ...nG tO prEVEnt SEriOUS inJUry anD DEatH FrOM EXplOSiOn Do not exceed 160 pSi 1 Adjust the Regulator Knob 1C so that the air output is enough to properly power the tool but the output will not exceed th...

Page 9: ...ressurized Look for air bubbles To clean the regulator surface wipe with a damp cloth using a mild detergent or mild solvent Weekly a Inspect Air Filter Quarterly every 3 months a Tool Disassembly Cle...

Page 10: ...E UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO...

Page 11: ...escription 1B Nipple 2B Elbow 3B Air Regulator 4B Plug 5B Air Valve 6B Gauge 1B 2B 5B 3B 4B 6B parts list and Diagram c part Description 1C Regulator Handle 2C Housing Cap 3C Spring Button 4C Spring 5...

Page 12: ...amages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS T...

Reviews: