![Central Pneumatic 39092 Assembly And Operating Instructions Manual Download Page 6](http://html1.mh-extra.com/html/central-pneumatic/39092/39092_assembly-and-operating-instructions-manual_2582263006.webp)
Page 6
SKU 39092
For technical questions, please call 1-800-444-3353.
Operation
For best service, you should incorporate an oiler, regulator, and inline filter, as
shown in the diagram below. Hoses, couplers, oilers, regulators, and filters are all avail-
able at Harbor Freight Tools.
Note:
For smoother operation and to extend the life-span
of the tool, put 3-5 drops of pneumatic tool oil in the attached Air Inlet (6432) before
each use.
Testing the Contact Safety Trip Mechanism
Warning: Even though the nailer should be empty during this procedure,
ALWAYS point the Nailer at a piece of scrap wood and wear ANSI
approved safety goggles when testing.
1.
Make sure the tool is disconnected from the air supply.
2.
Completely empty the Magazine (6465) of brads.
3.
The Nailer should not fire if the Safety Frame (6459) is not depressed against the
workpiece.
4.
Make sure the Trigger (6435) and Safety Frame (6459) move freely, without
sticking - see the illustration on the following page.
5.
Connect the air supply to the tool at the Quick Connector (6432). Set the regula-
tor at the recommended
70 PSI
to
125 PSI
.
Do not to go over the maximum
125 PSI.
6.
Test the tool by depressing the Safety Frame (6459) against the workpiece with-
out pulling the Trigger (6435).
The Tool must not cycle (fire).
If it cycles (fires),
TO
BRAD NAILER
REV 11/06