Central Hydraulics 92038 Assembly And Operating Instructions Manual Download Page 7

SKU 92038     For technical questions, please call 1-800-444-3353.         Page 7

SYMBOLOGY

Double Insulated

Canadian Standards
Association

Underwriters
Laboratories, Inc.

Volts Alternating Current

Amperes

No Load Revolutions
per Minute (RPM)

no

xxxx/min.

A

V ~

UNPACKING

When unpacking, check to make sure all the parts shown on the Parts List on page 11
are included.  If any parts are missing or broken, please call Harbor Freight Tools at the
number shown on the cover of this manual as soon as possible.

ASSEMBLY AND OPERATING INSTRUCTIONS

NOTE: For additional information regarding the parts listed in the following pages, refer
to the Assembly Diagram on page 12.

The Power Cord requires the attachment of a 220 volt, grounded, 3-Prong Plug
(not included).  For safety purposes, only a qualified, certified, electrician should
attach a Plug to the Power Cord.  Never modify the Plug in any way.  To comply with
the National Electric Code, and to provide additional protection from the risk of
electrical shock, this product should only be connected to a 220 volt electrical outlet
that is protected by a Ground Fault Circuit Interrupter (GFCI).

WARNING!

This pump can be used for a variety of applications.  However, it must ALWAYS be mounted
vertically to a stable, secure surface at least 18” from the floor and can only be used
with hydraulic systems and hoses rated at a working pressure of at least 2200 PSI.

1.

CAUTION: Always make sure the Power Cord of the Pump is unplugged from its
electrical outlet 

prior to installation.

Summary of Contents for 92038

Page 1: ...All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools For technical questions and replacement parts please call 1 800 444 3353 TO PREVENT SERIOUS INJURY READ AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS BEFORE USE 220 VOLT HYDRAULIC ELECTRIC PUMP R REV 12 04 ...

Page 2: ...G READ AND UNDERSTAND ALL INSTRUCTIONS Failure to follow all instructions listed below may result in electric shock fire and or serious injury SAVE THESE INSTRUCTIONS WORK AREA 1 Keep your work area clean and well lit 2 Do not operate electric pumps in explosive atmospheres such as in the presence of flammable liquids gases or dust Pumps may create sparks and arcing which may ignite the dust or fu...

Page 3: ...n sense when operating a the Pump Do not use the Pump while tired or under the influence of drugs alcohol or medication A moment of inattention while operating this Pump may result in serious personal injury 9 Dress properly Do not wear loose clothing or jewelry Contain long hair Keep your hair clothing and gloves away from moving parts Loose clothes jewelry or long hair can be caught in moving pa...

Page 4: ...isk of electric shock or injury SPECIFIC SAFETY RULES 1 Maintain labels and nameplates on the Pump These carry important information If unreadable or missing contact Harbor Freight Tools for a replacement 2 Always wear ANSI approved safety impact eye goggles and heavy work gloves when using the Pump Using personal safety devices reduce the risk for injury Safety impact eye goggles and heavy work g...

Page 5: ...le with pacemakers should consult their physician s before using this product Electromagnetic fields in close proximity to a heart pacemaker could cause interference to or failure of the pacemaker GROUNDING The Power Cord requires the attachment of a 220 volt grounded 3 Prong Plug not included For safety purposes only a qualified certified electrician should attach a Plug to the Power Cord Never m...

Page 6: ...re than one tool add the nameplate amperes and use the sum to determine the required minimum cord size See Figure C EXTENSION CORDS 6 If you are using an extension cord outdoors make sure it is marked with the suffix W A W in Canada to indicate it is acceptable for outdoor use 7 Make sure your extension cord is properly wired and in good electrical condition Always replace a damaged extension cord...

Page 7: ... The Power Cord requires the attachment of a 220 volt grounded 3 Prong Plug not included For safety purposes only a qualified certified electrician should attach a Plug to the Power Cord Never modify the Plug in any way To comply with the National Electric Code and to provide additional protection from the risk of electrical shock this product should only be connected to a 220 volt electrical outl...

Page 8: ... ends of a NPT 3 8 male connector not included Tighten one end of the male connector not included into the female connection see Assembly Drawing on page 12 6 Securely attach the other end of the connector to the hydraulic system Operation 1 Plug the Pump into an approved 220 Volt outlet 2 Press down on the Pressure Release Handle 3 to completely release hydraulic pressure 3 To pressurize the syst...

Page 9: ... the general condition of the Pump Check for loose screws misalignment or binding of moving parts cracked or broken parts leaking hydraulic fluid damaged electrical wiring and any other condition that may affect its safe operation If abnormal noise or vibration occurs have the problem corrected by a qualified technician before further use Do not use damaged equipment 3 Wipe the Pump clean with a l...

Page 10: ...THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION ORWARRANTY OF ANY KINDTOTHE BUYERTHAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATESTHAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED A...

Page 11: ... please call 1 800 444 3353 Page 11 NOTE Some parts are listed and shown for illustration purposes only and are not avail able individually as replacement parts ASSEMBLY DIAGRAM Hydraulic Oil Fill Female Connection 3 8 NPT Lift Button ...

Reviews: