You have now installed the Programmable Thermostat. For gas boiler applications, the factory system settings will not
need to be changed (for other applications see below). You can now use the USER GUIDE to program the unit and
demonstrate how it works to the homeowner.
Application
Settings
What to change
Using the Programmable Thermostat for Specific Applications
Cycle /Hour
Minimum ON time
Note: All parameters listed below belong to category 2
– system parameters (see Installer Parameter Table)
Gas Boiler (<30kW)
6
1
No changes required
Oil Boiler
3
4
Set 1:Ot parameter to 4
Set 2:Cr parameter to 3
Thermal Actuator
12
1
Set 2:Cr parameter to 12
Zone Valve
6
1
No changes required
Electric Heating
12
1
Set 2:Cr parameter to 12
(resistive load 3-5A)
Entering the Installer Mode
1.
Press the
OFF
button.
2.
Press and hold the button and the two
PROGRAM
and buttons together.
3.
The unit will display the first parameter of installer
parameter group category 1 (from Parameter No. 1 to
20).
4.
Press the or button to change the factory
setting. The display will flash indicating that a change
has been made.
5.
Press the
button to confirm the change. The display
will stop flashing.
6.
Press the button to go to the next parameter.
7.
Press the
PROGRAM
button to go to Installer
parameter group category 2 (from Parameter No. 1 to 5).
8.
To exit installer mode, press the
AUTO
,
MAN
or
OFF
button.