Safety Information for User & Installer

Important information for fitter:

Installation information

•  It is recommended that only approved/qualified plumbers should install the product.
•  Incorrect installation of the enclosure will invalidate guarantee. 

Safety information prior to and during installation

•  Carefully check the product for transport damage prior to installation. 
•  Never install damaged panels as there is a risk of spontaneous glass breakage.
•  The supplied fixings/wall plugs are 

only

 for mounting directly on solid walls. 

•  It is essential that the solid, masonry/walls be inspected for adequate load-bearing capacity prior to every installation.
•  The supplied fixings/wall plugs are 

not for use

 with stud walls such as plaster board, wood, metal or fiber board.

• 

 Always seek professional advice to confirm wall type and appropriate type of fixing to be used for installation.

•  Always check walls for concealed utility lines (power, gas, and water) prior to drilling the fixing holes. 
•  Ensure that fittings will not hinder the movement of the door as this may cause glass breakage.
•  For hinge/pivot doors ensure that toilet bowls, wash-stands or other objects are outside of the door opening area.

Special information on handling glass

•  Always protect all glass edges from damage.
•  Never stand the glass on its corners throughout the installation! Place the packing material beneath the glass panel;

  never place the glass on tiles, concrete floors or similarly hard surfaces

•  It is mandatory to check each glass panel for damage prior to installation. Never install damaged glass panels as this

  could cause spontaneous glass breakage!

•  If the glass panel is damaged during use it must be replaced without delay. (Failure could cause a risk of spontaneous

  glass breakage!)

Prevent damage to glass or operation of the product. 

•  Ensure fittings do not hinder the movement of the door. 
•  Ensure that no objects are within the range of the door opening/ closing area. 
•  Avoid hitting the panels with hard objects such as mops when cleaning or tools during assembly. Damaged panels

  must be replaced as failures may cause latent glass breakage.

•  Do not hit against the glass edge with hard or pointed objects (e.g. with mop handle) Damaged panels must be

  replaced; damage may cause spontaneous glass breakage.

•  Do not use panels or handles to hang or support items such as drying towels or clothes.  

Hazard information for special groups of people

•  Do not allow small children, sick or disabled persons to shower unattended.
•  A strong magnet is attached in the closing profile of some of the panels. This magnet could affect a pacemaker. Keep

  a minimum distance of 15 cm from the magnet. Consult insulation guide for location of magnets.

Maintenance Information

Service/repair and inspection required for safety

•  After cleaning, check all the moving elements are sufficiently greased, re-grease, if necessary. Only use acid-free

  grease. We recommend silicone grease or standard household Vaseline.

Cleaning 

Do not use steam cleaners, caustic or aggressive cleaning and scouring agents, cleaners that corrode
plastics, or solvents containing acetone or turpentine or neat bleach.

•  Do not use any cleaning agents, which according to the manufacturer's specifications may corrode aluminum or light

  alloys. 

•  Do not use glass cleaning pastes and micro-fiber cloths to prevent damage to glass coating system.
•  In order to prevent the build-up of lime scale, remove any remaining drops of water after showering using a squeegee,

  soft cloth without any cleaning agent.

•  After use, carefully rinse off all residue such as; liquid soaps, shampoos, shower gels or similar cosmetic product with

  water to avoid deposits. 

Important: 

Never apply the cleaning agent for longer than necessary. After cleaning, check all the moving elements

                      are sufficiently greased, re-grease, if necessary.

Summary of Contents for D02161

Page 1: ...INSTALLATION INSTRUCTIONS WARRANTY LEAFLET Center Quad 4mm Enclosure 800x800x1850 Center Quad 4mm Enclosure 900x900x1850 D02161 D02162 ...

Page 2: ...that the installation kit is complete DO NOT ALL 4 boxes as satisfactory The wall plugs supplied with the installation kit are for use in solid walls Hollow or stud partition walls will require alternative fixings Please consult a hardware supplier for the correct type It may also be necessary to consult your tiling supplier about the correct method for drilling your tiles attempt to install the pr...

Page 3: ...35 12 2xHandle Sets 11 4xGlass Clamps 4xScrews ST3 5x8 2 6xWall Plugs 3 6xScrews ST4x35 4 12xScrews Cover Caps 5 6xScrews ST3 5x8 13 4xWater Deflectors 7 2xFixed Panels 14 2xMagnetic Seals 6 2xWall Posts 8 2xDoor Panels 9 4xTop Rollers 10 4xBottom Rollers 15 4xProfile Covers ...

Page 4: ...code 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 2 6 14 12 10 2 2 2 4 4 4 2 4 2 4 Horizontal Rails Wall Plugs Screws ST4x35 Screws Cover Caps Screws ST3 5x8 Wall Posts Fixed Panels Door Panels Top Rollers Bottom Rollers Glass Clamps Handle Sets Water Deflectors Magnetic Seals Profile Covers N N Y N N N N N Y N Y N D03091 D03102 D03097 D03098 Y D03093 Y ...

Page 5: ...A A SIZE mm A 800x800 900x900 770 790 870 890 A A Adjust The Size 4 ...

Page 6: ...om inside Please note installation direction of the glass clamp Screw ST3 5x8 Screw ST4x35 6mm 6 2 3 7 Glass Clamp Glass Clamp Screw M4x35 2b 11 1 3 The profile must be checked with the spirit level whilst marking 2b 2b 4 5 with screw cover 4 ...

Page 7: ...Step 3 Step 4 1 2 View from inside View from inside 7 6 1 2 9 10 8 Top Roller Top Roller Bottom Roller 6 ...

Page 8: ...Step 5 Step 6 3 2 3 Fixed Panel Door Panel Ensure wall profiles are plumb Adjust enclosure to be square and level Wheels should be adjusted to square the doors and ensure smooth running 2 3 1 13 14 12 7 ...

Page 9: ... Max 3 0mm Screw ST3 5x8 View from inside 4 5 15 Take extra care not to drill through to exterior side with screw cover 8 Follow the indications on wall profiles to locate the drilling holes The sealant should be applied to the outside edge 4 ...

Page 10: ...ct Ensure fittings do not hinder the movement of the door Ensure that no objects are within the range of the door opening closing area Avoid hitting the panels with hard objects such as mops when cleaning or tools during assembly Damaged panels must be replaced as failures may cause latent glass breakage Do not hit against the glass edge with hard or pointed objects e g with mop handle Damaged pane...

Page 11: ...ny technical help in association with your CENTER products please call with your query 0344 292 7062 Warranty Years For detail warranty information please visit our website www wolseley co uk 5 Wolseley CV34 6DY www wolseley co uk ...

Reviews: