![Cengar JP901 Operating Instructions Manual Download Page 8](http://html.mh-extra.com/html/cengar/jp901/jp901_operating-instructions-manual_2581490008.webp)
IF THE SAW DOES NOT OPERATE
1
Check that the isolator is switched on.
2
Check air supply is correct.
3
Valve in handle (part no. 50034) could be worn and/or the seal
is broken, blocking an air passage. Check and replace if
necessary.
4
Ensure that all valve moun ng screws in the body are ght, and
that air is not escaping from the gaskets at the front or rear.
5
Ensure the oil container is
fi
lled with Cengar Green Oil, leaving
a small air bubble to prevent ‘Hydraulic Lock’.
MAINTENANCE
REPLACEMENT OF TRIGGER VALVE - PART NO. 50034
To replace the trigger valve, loosen the six main screws securing
the valve block, but do not remove, this will allow the trigger bar
to be drawn out, revealing the valve.
Replace the valve, un l it is level with the top of the hole, re
fi
t the
trigger bar, and
fi
nger ghten screws. Reconnect air supply, and
check opera on of trigger. No air should
fl
ow when released, full
air should
fl
ow when depressed, if needed adjust height of valve
1
/
4
of a turn either way.
Re
‐
ghten the six screws evenly and
fi
rmly.
Always
remove
the
saw
from
the
airline
before
commencing
any
maintenance
work.
Only
fi
t
genuine
Cengar
parts
and
accessories,
or
safety
may
be
compromised
Summary of Contents for JP901