background image

PNB-7KE 

SAFETY 

Designated use 

The PNB-7KE is to be used exclusively for crimping wire-end ferrules with cross sections between 4 

and 10 mm². Under no circumstances should large metal parts or similar objects be introduced; the 

die set will be ruined. 
Unauthorised amendments to the PNB-7KE are prohibited for safety reasons! 

!

Observation of all instructions and compliance with the prescribed operating 

conditions are part of the designated use. 

Sources of danger 

The PNB-7KE must only be operated when the finger guard plate is screwed on. 
Only filtered compressed air with a maximum pressure of 6 bar can be used. 
Disconnect the machine from the compressed air before working on the PNB-7KE, during breaks 

and when the device is not in use. Do 

not

 pull on the compressed air tubing to disconnect. 

Work places 

The following should be avoided for operation and storage: 

  damp or dusty places, 

  places which are subject to high levels of heat, direct sunlight or low temperatures (operating 

range: 15 °C to 35 °C). 

Protect the compressed air tubing from heat, oil and sharp edges.  

Safety devices 

The PNB-7KE has a finger guard plate at the front as a contact safety device. 
Under no circumstances should this be removed. 
The PNB-7KE is stopped when disconnected from the compressed air supply. 

Permitted operators 

Only authorised and instructed operators can work on the PNB-7KE. 
The operator is responsible to third parties in the working area. 
The owner must 

  make the operating instructions available to the operator and 

  make sure that the operator has read and understood them. 

17 

2

Summary of Contents for PNB-7KE

Page 1: ...rid Espa a Tel fono 91 4852580 Telefax 91 4852581 E mail info cembre es Cembre AS Fossnes Senter N 3160 Stokke Norway Phone 47 33361765 Telefax 47 33361766 E mail cembre cembre no Cembre GmbH Heideman...

Page 2: ...accident or injury hazard and or possible damage to the PNB 7KE indicates notes on application Dangerousness of the machine The PNB 7KE has been constructed according to recognised technical safety r...

Page 3: ...NB 7KE during breaks and when the device is not in use Do not pull on the compressed air tubing to disconnect Work places The following should be avoided for operation and storage damp or dusty places...

Page 4: ...arantee and liability claims resulting from damage to personnel or property are inadmissible if the following points have been violated Non designated use of the PNB 7KE Inappropriate working places I...

Page 5: ...1 Molla 2502 5 Molla 2506 12 Piastrina protezione dita 10000 6 Testa completa 10040 13 Supporto Magnetico A richiesta 7 Corpo testa 10005 PNB 7KE DESCRIPTION Application The PNB 7KE is a pneumatic cri...

Page 6: ...lle matrici 4 vengano correttamente inseriti nel pistone 3 PNB 7KE OPERATION Commissioning Fig 2 Putting into operation Check whether finger guard plate 1 is present and is sitting firm Check whether...

Page 7: ...interno del foro 1 relativo alla sezione da comprimere Premere la leva 2 per iniziare il processo di compressione Rilasciare la leva 3 il cavo aggraffato pu essere rimosso 4 Fig 3 Compressione PNB 7KE...

Page 8: ...Leva 3 Corpo 4 Testa 5 Matrici di compressione 6 Protezione antinfortunistica per le dita Accessori 7 Supporto magnetico PNB 7KE SPARE PARTS The following spare parts can be ordered with the appropria...

Page 9: ...difiche strutturali e non autorizzate alla PNB 7KE Uso continuato della PNB 7KE anche quando in atto un malfunzionamento Riparazioni effettuate in modo inadeguato Usare solamente parti di ricambio ori...

Page 10: ...nato solamente al personale autorizzato ed adeguatamente istruito L operatore responsabile verso terzi nell ambito della propria area di lavoro Il datore di lavoro deve rendere disponibile il manuale...

Reviews: