PNB-7KE
SAFETY
Designated use
The PNB-7KE is to be used exclusively for crimping wire-end ferrules with cross sections between 4
and 10 mm². Under no circumstances should large metal parts or similar objects be introduced; the
die set will be ruined.
Unauthorised amendments to the PNB-7KE are prohibited for safety reasons!
!
Observation of all instructions and compliance with the prescribed operating
conditions are part of the designated use.
Sources of danger
The PNB-7KE must only be operated when the finger guard plate is screwed on.
Only filtered compressed air with a maximum pressure of 6 bar can be used.
Disconnect the machine from the compressed air before working on the PNB-7KE, during breaks
and when the device is not in use. Do
not
pull on the compressed air tubing to disconnect.
Work places
The following should be avoided for operation and storage:
damp or dusty places,
places which are subject to high levels of heat, direct sunlight or low temperatures (operating
range: 15 °C to 35 °C).
Protect the compressed air tubing from heat, oil and sharp edges.
Safety devices
The PNB-7KE has a finger guard plate at the front as a contact safety device.
Under no circumstances should this be removed.
The PNB-7KE is stopped when disconnected from the compressed air supply.
Permitted operators
Only authorised and instructed operators can work on the PNB-7KE.
The operator is responsible to third parties in the working area.
The owner must
make the operating instructions available to the operator and
make sure that the operator has read and understood them.
17
2