5-9.Continuity Check
To avoid electric shock, disconnect power to the unit under test and discharge all
capacitors before taking any resistance measurements. Remove the batteries and unplug
the line cords.
WARNING:
1.Set the function switch to the green
Ω CAP
position.
2.Press the soft key labeled Menu. Move the
menu selector to the menu item labeled
Beeper. Press the soft key Beeper.
3.Insert the black test lead banana plug into
the negative COM jack. Insert the red test
lead banana plug into the positive jack.
4.If the resistance is less than approximately
25Ω, the audible signal will sound. If the
circuit is open, the display will indicate “OL”.