background image

7.Menus

The menus, together with buttons, are access for image, measurement, Emiss, Palette, temperature

measurement range, take photo and video, review, and settings.

Main Menu is the main interface of the Thermal Imager’s

menus. It contains six items such as Measure, Emiss, Image,
Palette, Temperature measurement range, Settings.

set for the calculation and display of radiometric

temperature measurement data related to the thermal images.

Setting the materials type and the emissivity of the

measured object, you can also set the environment reflected
temperature.

set image source for the display on the Thermal

Imager’s LCD. It contains six items such as infrared image,
visual image and fusion.

set the type of color bar.

set the temperature measurement range.

set for the user preferences such as language, unit

of temperature measurement, date, time. restore factory setting and display product information.

In main menu, press “up” and “down” button, highlight “Image”.
Press “select” button, popup Image submenu which contains infrared image, visual image and fusion.
Press “up” and “down” button, highlight the Image mode which you want to choose.
Press “Select” to confirm, “Close” to exit without change.

Thermal Imager has 3 kinds of image modes for display. IR, Visible, IR_Mix_VIS, AUF mode.

displays only infrared image;

displays only visible image;

display fusion image of infrared and visible images.

Auto Fusion mode, compare the centre area temperature with full screen, the machine will calculate

the mix ratio of infrared and visible images automaticly.

7.1-Main Menu

Measure:

Emiss:

Image:

Palette:
Range:
Settings:

7.2-Image Mode

IR:
Visible:
IR_Mix_VIS:
AUF:

1-
2-
3-
4-

(Patent Num: PCT/CN2016/079015)

Thermal Imager User Manual

4

14

Summary of Contents for DT-982

Page 1: ...Please read this manual before switching the unit on Important safety information inside Thermal Imager User Manual 160 x 120 Pixels AUF Auto Fusion function Patent Num PCT CN2016 079015...

Page 2: ...Thermal Imager User Manual...

Page 3: ...ll 12 3 Running 12 4 Uninstall Introduction Safety Information Packing lists Specifications Structure Description Before You Start 7 Menus 8 Fault diagnosis and exclusion 12 PC software Back View Fron...

Page 4: ...equipment to discharge the battery If you do not use the correct equipment you can decrease the performance or the life cycle of the battery If you do not use the correct equipment an incorrect flow o...

Page 5: ...th and a weak soap solution Do not use abrasives isopropyl alcohol or solvents to clean the case or lens screen Be careful when you clean the infrared lens Do not clean the infrared lens too vigorousl...

Page 6: ...tal lens data 19 x 25 0 5m 2 78mrad 0 1 C 30 C 86 F 100 mK 50Hz Manual 1 32 x continuous digital zoom 9mm Uncooled microbolometer 8 14 m 160 x 120pixels 2 8 in LCD 240 x 320 pixels IR image Visual ima...

Page 7: ...en camera and PC Live video between camera and PC HDMI Li ion battery 4 hours operating time DC 5V In camera AC adapter Automatic shutdown 15 C to 50 C 5 F to 122 F 40 C to 70 C 40 F to 158 F 10 90 2m...

Page 8: ...t Visual Camera Laser Pointer Infrared Camera Lens Hole for Tripod Insertion Charge Light USB Cable Connection Charger Input Terminal Audio Microphone HDMI Output Micro SD Card 8 9 10 11 12 13 14 15 1...

Page 9: ...the battery is full charged Make sure that the Thermal Imager is near room temperature before you connect it to the charger Do not charge in hot or cold areas When you charge in extreme temperature ba...

Page 10: ...FOV is 25 the IFOV is 25um 9mm 2 78mrad D S theoretical 1 IFOV theoretical 359 1 D Smeasure 1 IFOV measure is the spot size needed to provide an accurate temperature measure Typically D Smeasure is 2...

Page 11: ...ermal Imager need to correct The Thermal Imager has two mode for correcting Manual and Auto Mode In Manual Mode push the Power button the Thermal Imager will correct In Auto Mode the Thermal Imager ca...

Page 12: ...ity Adjustment to get the most accurate temperature measurements The correct emissivity value is important to make the most accurate temperature measurement Emissivity of a surface can have a large ef...

Page 13: ...missivity The reflected temperature can be set individually Follow these steps to get the right value for the reflected temperature Set the emissivity to 1 0 Adjust the optical lens to near focus Look...

Page 14: ...ange set for the user preferences such as language unit of temperature measurement date time restore factory setting and display product information In main menu press up and down button highlight Ima...

Page 15: ...ght the palette which you want to choose Press Select button to select palette press Close button to return There are two kinds of mode for image adjustment Auto and Manual Press right function button...

Page 16: ...apture minimum temperature Open and Close Object Parameter Menu Press Select to select Spot Hot Cold to open the corresponding point of the temperature measurement The icon means to open corresponding...

Page 17: ...perature measurement accurately set the reflective temperature In most cases the reflected temperature is identical to the ambient temperature Only when objects with strong emissions with much higher...

Page 18: ...u Press up and down button highlight the Range which you want to choose Press Select to confirm Close to exit without change In main menu press up and down button highlight Settings Press select butto...

Page 19: ...utton to confirm Close to exit without change In Settings submenu press up and down button highlight Temp Unit Press select button popup Temperature Unit submenu Press up and down button highlight the...

Page 20: ...hange Factory Settings of the Thermal Imager is as follow 1 2 3 Parameter Center Spot Measurement Hot Spot Measurement Cold Spot Measurement Emissivity Reflective temperature Mode Palette Adjustment L...

Page 21: ...ubmenu Press Left and Right button highlight the item which you want to choose Press Up and Down button modify the value of the selected item In Settings submenu press Up and Down button highlight Inf...

Page 22: ...lect button popup Auto power off submenu Press up and down button highlight the item which you want to choose Press Select to confirm Close to exit without change The Thermal Imager will shut down aft...

Page 23: ...ermal Imager PC software In desktop press Trigger button freeze an image Press Save key save image and show the file name saved press Cancel return desktop without saving image The Thermal Imager has...

Page 24: ...ft button to open previous image Press Right button to open next image To return files browser Press Browse key To return desktop Press Files browse button again or press Exit key Press up down left a...

Page 25: ...d file Press Up and Down button highlight Delete all Press OK key Delete all file Press Up and Down button highlight Exit Press OK key return desktop Press Close return files Browser Connect USB cable...

Page 26: ...connect the Thermal Imager proceed as follows Connect the Thermal Imager to the external HDMI monitor or recording device using the HDMI video cable provided Turn on the external HDMI monitor or devic...

Page 27: ...Play and install it IOS Search Thermview on Apple Store and install it Use the USB OTG cable download the IR pictures from the thermal imager directly Copy the IR pictures from PC or SD card Software...

Page 28: ...mode there are four mode for you to select IR mode only infrared picture displayed Visible mode only visible picture displayed IR fusion mode The infrared picture is fusioned with visible picture Vis...

Page 29: ...it will display the temperature of the point Line analyse Add a line to the picture it will display the highest lowest and average temperature of the line Area analyse Add a rectangle to the picture i...

Page 30: ...k 3 5 include 2 0 when you install PCIMeter software If not please find and install our Microsoft NET_Framework_v2 0 exe that provided to you Open the net framework 2 0 Follow all tips to install Net...

Page 31: ...click Finish like above After ensuring PCIMeter software has been installed click shortcuts on the desktop or start menu to run the software Uninstall PCIMeter in the start menu as follow then click...

Page 32: ...Rev 160523...

Reviews: