True RMS Autoranging Digital Multimeter

  3-2.Symbols Used on LCD Display

    1-Display Hold
    2-Units of Measure List
    3-Percent (Duty Ratio)
    4-Battery Status
    5-Auto Power Off
    6-Measurement Reading
    7-Autoranging
    8-Minimum
    9-Maximum
    10-Relative
    11-Continuity
    12-Diode Test
    13-Minus Sign
    14-Alternating Current
    15-Direct Current
    16-Frequency Conversion

Measure

Summary of Contents for DT-9560

Page 1: ...Operating Instruction for Heavy Duty Industrial True RMS Autoranging Digital Multimeter with VFD Measurement Please read this manual before switching the unit on Important safety information inside...

Page 2: ......

Page 3: ...AC Voltage Frequency Duty Cycle Measurements 4 3 mV Voltage Measurements 4 4 DC Current Measurements 4 5 AC Current Frequency Duty Cycle Measurements 4 6 Resistance Measurements 4 7 Continuty Check 4...

Page 4: ...entially hazardous situation which if not avoided could result in death or serious injury This CAUTION symbol indicates a potentially hazardous situation which if not avoided may result damage to the...

Page 5: ...itches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation Overvoltage Category IV Equipment of Overvoltage Category IV is for use at th...

Page 6: ...de Doing so can damage the meter 2 3 5 ALWAYS discharge filter capacitors in power supplies and disconnect the power when making resistance or diode tests 2 3 6 ALWAYS turn off the power and disconnec...

Page 7: ...klight Button Function Switch 8 9 10A Input Jacks 10 mA Input Jacks A 11 Positive Input Jacks 12 COM Input Jacks 13 Tilt Stand 14 Battery Cover 13 14 RANGE MODE REL Hz HOLD MAX MIN OFF CAP mA Auto Pow...

Page 8: ...ed on LCD Display 1 Display Hold 2 Units of Measure List 3 Percent Duty Ratio 4 Battery Status 5 Auto Power Off 6 Measurement Reading 7 Autoranging 8 Minimum 9 Maximum 10 Relative 11 Continuity 12 Dio...

Page 9: ...on the circuit is being switched ON or OFF Large voltage surges may occur that can damage the meter 1 Set the function switch to the VDC position 2 Insert the black test lead banana plug into the nega...

Page 10: ...Indicate AC on the display 2 Insert the black test lead banana plug into the negative COM jack Insert red test lead banana plug into the positive V jack 3 Touch the black test probe tip to the neutral...

Page 11: ...e surges may occur that can damage the meter 1 Set the function switch to the mV AC DC position 2 Press the MODE button to indicate DC or AC 3 Insert the black test lead banana plug into the negative...

Page 12: ...plug into the A mA jack 4 For current measurements up to 10A DC set the function switch to the 10A AC DC position and insert the red test lead banana plug into the 10A jack 5 Press the MODE button to...

Page 13: ...ack 3 For current measurements up to 600mA AC set the function switch to the mA AC DC position and insert the red test lead banana plug into the A mA jack 4 For current measurements up to 10A AC set t...

Page 14: ...ack Insert the red test lead banana plug into the positive jack 3 Press the MODE button to indicate on the Display 4 Touch the test probe tips across the circuit or part under test It is best to disco...

Page 15: ...plug into the positive jack 3 Press the MODE button to indicate and on the display 4 Touch the test probe tips to the circuit or wire you wish to check 5 If the resistance is less than approximately...

Page 16: ...V on the display 4 Touch the test probes to the diode under test Forward voltage will typically indicate 0 400 to 0 700V Reverse voltage will indicate OL Shorted devices will indicate near 0V and an o...

Page 17: ...COM jack Insert the red test lead banana plug into the positive V jack 3 Press the MODE button to indicate nF on the display 4 Touch the test leads to the capacitor to be tested 5 The test may take u...

Page 18: ...nging Manual Range Selection When the meter is first turned on it automatically goes into Autoranging This automatically selects the best range for the measurements being made and is generally the bes...

Page 19: ...mum reading and will update only when a new min occurs 3 To exit MAX MIN mode press and hold the MAX MIN key for 2 seconds 4 13 Relative Mode The relative measurement feature allows you to make measur...

Page 20: ...activate or to exit the HOLD function 4 16 Auto Power Off The auto off feature will turn the meter off after 15 minutes To disable the auto power off feature hold down the MODE button and turn the met...

Page 21: ...damp cloth do not use chemicals cleaning solvents or detergents 5 Use only fresh batteries of the recommended size and type remove old or weak batteries so they do not leak and damage the unit 6 If th...

Page 22: ...om the meter 2 Remove the battery cover 3 Gently remove the old fuse and install the new fuse into the holder 4 Always use a fuse of the proper size and value 800mA 1000V fast blow for the 600mA range...

Page 23: ...ts 0 5 5 digits 0 6 6 digits 0 9 9 digits 0 8 3 digits 0 8 8 digits 4 3 digits 1 0 3 digits 1 5 3 digits Resolution 0 01mV 0 1mV 0 001V 0 01V 0 1V 1V 0 01mV 0 1mV 0 001V 0 01V 0 1V 1V 0 1V 1V 0 1 A 1...

Page 24: ...2 digits 1 2 2 digits 1 0 5 digits 5 0 20 digits 4 0 5 digits 10 reading Resolution 0 1 A 1 A 0 01mA 0 1mA 0 001A 0 01A 0 1 0 001k 0 01k 0 1k 0 001M 0 01M 0 01nF 0 1nF 0 001 F 0 01 F 0 1 F 0 001mF 0...

Page 25: ...20 to 80 duty cycle and 100kHz 5Vrms min at 20 to 80 duty cycle and 100kHz Frequency Electrical Sensitivity ACmV Range 100mV ACV Range 6 Range 6000 A 600 0mA 10 00A Range 6 Range 600 0 A 60 00mA 6 00...

Page 26: ...range 10A 1000V ceramic fast blow 5 to 40 C 41 to 104 F 20 to 60 C 4 to 140 F Max 80 up to 31 C 87 F decreasing linearly to 50 at 40 C 104 F 80 2000 meters 7000 ft maximum This meter is intended for...

Page 27: ......

Page 28: ...Rev 190604 True RMS Autoranging Digital Multimeter...

Reviews: