11
RESISTANCE [ Ω ] MEASUREMENT
WARNING:
To avoid electric shock, disconnect power to the
unit under test and discharge all capacitors before taking any
resistance measurements. Remove the batteries and unplug the
line cords.
1. Set the function switch to the
Ω
position.
2. Insert the black test lead plug into the negative (COM) socket
and the red test lead plug into the positive Ω jack.
3.
Press the MODE button until “Ω”
appears in the display.
4. Touch the test probe tips across the circuit or part under test. It is
best to disconnect one side of the part under test so the rest of
the circuit will not interfere with the resistance reading.
5. Read the resistance in the display. The display will indicate the
proper decimal point, value and symbol.
CONTINUITY CHECK
WARNING:
To avoid electric shock, never measure continuity
on circuits or wires that have voltage on them.
1. Set the range switch to the
•
))) position.
2. Insert the black lead plug into the COM socket and the red
test lead plug into the positive
•
))) socket.
3. Press the MODE button until “
•
)))” appears in the displa
4. Touch the test probe tips to the circuit or wire you wish to
check.
5. If the resistance is less than 35
Ω, the audible signal will sound.
The display will also show the actual resistance in ohms.
Summary of Contents for DT-5302
Page 2: ...1...
Page 16: ...15 V06 08...