CEM DT-360 Operating Instruction Download Page 2

Meter Description 

1.  Current clamp 

2.  Non-contact AC voltage indicator light 

3.  Clamp trigger 

4.  Rotary Function swith 

5.  Data Hold button 

6.  Back light button 

7.  LCD display 

8.  MODE select button 

9.  Range  button 

10. MAX    hold button 

11. COM input jack 

12. 

Ω

CAP 

TEMPHz

 jack

 

13. 

Battery Cover

 

 

 

 
 

1. 

 AC  DC 

     AC (alternating current)  

and DC (direct currrent) 

2.                    Minus sign 

3. 

8.8.8.8

 

  2000 count (0 to 1999)  

measurement reading  

4. 

AUTO 

       AutoRange mode 

5. 

REL 

          Relative mode 

6.                     Diode test mode  

7.     

•)))

          Audible Continuity 

8.

 

HOLD 

       Data Hold mode 

 

9.

 

,

,

 

µ

,m,V,A,K,M,

Ω

,

 Units of measure list 

10.

 

 MAX              

MAX hold mode

 

 

 

 

Specifications

 

Function 

Range & Resolution 

Accuracy (% of reading) 

AC Current 

(50/60Hz) 

2.000AAC 

± (2.5 % + 10

 digits

)

 

20.00AAC 

± (2.5 % + 4

 digits

200.0AAC 

± (2.5 % + 4

 digits

400.0 AAC 

± (3 % + 4

 digits

)

 

DC Voltage 

200.0 mVDC 

± (0.8% + 2 digits) 

2.000 VDC 

± (1.5% + 2digits) 

20.00 VDC 

200.0 VDC 

600.0 VDC 

± (2 % + 2

 digits

)

 

AC Voltage 

 

200.0 mVAC 

± (1.5% + 35 digits) 

2.000 VAC 

± (1.8% + 8 digits) 

20.00 VAC 

200.0 VAC 

600.0 VAC 

± (2.5% + 8

 digits

)

 

Resistance 

200.0 

Ω

 

± (1.0% + 4 digits) 

2.000K

Ω

 

± (1.5% + 2 digits) 

20.00K

Ω

 

200.0K

Ω

 

2.000M

Ω

 

± (2.5% + 3 digits) 

20.00M

Ω

 

± (3.5% + 5 digits) 

    
 
 
Clamp size                           

Opening 1.2" (30mm) approx 

Diode Test

 

                   

Test  current of 0.3mA typical; Open circuit voltage 1.5V DC 

typical. 

Continuity Check

 

      Threshold <150

; Test current < 0.5mA 

Low Battery Indication

     “          ” is displayed 

Overrange Indication 

   

“OL””  is displayed 

Measurements Rate          

2 per second, nominal 

Input Impedance

 

       10M

 (VDC and VAC) 

Display 

2000 counts LCD 

AC Current 

50-60Hz (AAC) 

AC Voltage bandwidth  

50-60Hz (VAC) 

Operating Temperature 

41 to 104

o

F (5 to 40

o

C)

 

Storage Temperature

 

  -4 to 140

o

F (-20 to 60

o

C) 

Operating Humidity 

Max 80% up to 87

°

F (31

°

C) decreasing linearly to 50% at 

104

°

F(40

°

C) 

Storage Humidity 

<80%  

Operating Altitude 

7000ft. (2000meters) maximum. 

Over voltage

   

Category III 600V 

Battery

 

One 9V Battery

 

Auto OFF

 

approx. 15 minutes  

Dimensions/Weight

 

     197x70x40mm/183g 

Safety                                    

For indoor use and in accordance with Overvoltage Category 

II, Pollution Degree 2. Category II includes local level, 

appliance, portable equipment, etc., with transient 

overvoltages less than Overvoltage Cat. III 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 