PhySicAl
Size
- Board Only
180 x 120 x 20mm
(7.1” x 4.7” x 0.8”)
- Enclosure
460 x 250 x 90mm
(18” x 10” x 3.5”)
Weight
- Board Only 0.1Kg
- Enclosure 5.00kg
Housing
Wall mounting 1.2mm steel enclosure
Colour
Grey
Power
- Board Only:
- Voltage
11 – 15Vdc
- Current
Consumption
300mA (excluding locks
and heads)
Enclosure:
Voltage
220-230 VAC 50/60Hz.
Current
Consumption
450mA (excluding locks and heads)
Backup Battery
Integral charging circuit provided with
enclosure and space battery
(Battery not supplied).
Environmental
- Temperature
-20º to 70°C (-4° to 158°F)
- Humidity
95% non condensing
LED Indicators
Power, Link to host, Comms Tx/Rx, Fault /
Tamper, Lock and Relay Status
FUncTionAliTy
Inputs
* Door Position
* Lock Status
* Exit Push Button
* General Purpose
Inputs continued
Break Glass Sense
Fire Alarm Sense
Power Fail
Tamper
Battery Low (reported internally)
Dedicated Power Fail Input
* = 4 state tamper protected inputs
Outputs
Two 12V or 24V open collector outputs
limited to 1.5A
(Door Lock and External Sounder)
Two Relays rated at 35V@2A
Reader capacity
2 Weigand/Mag Stripe interfaces (data/
data, clock/data)
Configuration
Operational parameters are downloaded
from host computer.
commUnicATion inTERFAcE
To Readers
Weigand/Mag Stripe interface (data/data,
clock/data)
- Connection
2 part screw terminals
To System Host
RS485 multidrop cable runs using copper
wire with maximum length of 1.2km
without repeater
- Connection
2 part screw terminals
PRodUcT codES
DCM/150/105
DCM 150 (Board Only)
DCM/150/101
DCM 150 (Includes enclosure, board &
power supply/battery charger)
CEM Systems Ltd Unit 4 Ravenhill Business Park Ravenhill Road Belfast BT6 8AW Northern Ireland
Tel: +44 (0)28 9045 6767 Fax: +44 (0)28 9045 4535 email: [email protected]
www.cemsys.com
connect to existing read head technology
The DCM 150 is suitable for installations where customers
want to connect existing read head technology to any of CEM’s
intelligent controller products like webEntry or the S9032/
S9064 with AC2000 SE. Unlike the CEM range of card readers the
DCM 150 does not provide local database support for off-line
card validation.
Ease of installation
Visual confirmation of board, relay and comms transmit/receive
status is provided via LEDs allowing easy installation and
simplifying the diagnostic process. An onboard LED provides
visual alerts to help when a number of DCM’s are banked in
close proximity to one another.
High quality connectors simplify the installation process and
allow simple drop in replacement in the event of hardware
failure. Board configuration is achieved via a small number of
jumpers and requires no specialist tools.
PRodUcT highlighTS
CEM/B/040 Rev C
Product specifications and availability is subject to change without notice. Certain product names mentioned herein may be trade names
and/or registered trademarks of their companies.
TEchnicAl SPEciFicATionS