background image

 

 

   

 

 

 
 

 

    

 

 

 

 

 

 

7.Fix timber sheets to rafters using 
self tapping screws at 200mm centres 

Fakro Window to be fitted to the V 
Notch 

Tiling always to start at the bottom left of the roof. Always start with a full tile with a 
half tile above. 

Felt roof using suitable breather 
membrane. The overhang is 200mm. 

Fakro Tile Flashing installed with 
Guardian Roof Tile 

Summary of Contents for Guardian Roof

Page 1: ...lan and this guide Your fabricator will be available at all reasonable times to provide installation technical support Roof Layout Plan Please refer to the roof layout plan prior to commencing installation It is very important that the roof fits the windows layouts and that all the windows are reinforced All components are numbered to match the roof layout plan for ease of installation Sealing At ...

Page 2: ...t issues this guide without warranty or guarantee of any kind and accepts no responsibility as to how the information is interpreted Health and safety regulations are the sole responsibility of the installer and totally unconnected to Celuplast Ltd The Guardian Roof is continually evolving and changes to product and specification can change at any time Updates to this guide will be posted on our w...

Page 3: ...All window frames must be reinforced in order to take the weight of the Guardian Roof It is the sole responsibility of the installer to establish that the window frames are reinforced ...

Page 4: ...Components Box Gutter ...

Page 5: ...1 Fix window frame to ring beam using self tapping screws at a maximum if 600mm centres 2 Fix ring beams together using ring beam cleats ...

Page 6: ...ther using cleats and self tapping screws 4 Connect rafters to ring beam using cleats and bolts provided 6 Gable rafters to be secured to the house wall using suitable fixings depending on wall structure Typical Spider assembly using pins and locking nuts provided ...

Page 7: ...tres Fakro Window to be fitted to the V Notch Tiling always to start at the bottom left of the roof Always start with a full tile with a half tile above Felt roof using suitable breather membrane The overhang is 200mm Fakro Tile Flashing installed with Guardian Roof Tile ...

Page 8: ...appings to be screwed from the side and hidden using the Guardian Tile repair kit Gutter brackets twist lock into the ring beam and Gutter locks on to brackets Box Gutter adapter fitted into the box gutter and sealed using suitable wet sealant Gutter joint then fitted to adapter for continuation around ring beam ...