“Combi” Gas-Fired Boiler/Water Heater
Model 35 BF
Installation and Operating Instructions
CLIOM-1
315 Oser Avenue • Hauppauge, NY 11788Tel: (631) 694-1800 • Fax: (631) 694-1832www.embassyind.com
Page 1: ...Combi Gas Fired Boiler Water Heater Model 35 BF Installation and Operating Instructions CLIOM 1 315 Oser Avenue Hauppauge NY 11788 Tel 631 694 1800 Fax 631 694 1832 www embassyind com...
Page 2: ...act zone between drinking water and the water used for the heating system d clare que a Les mat riels utilis s l int rieur de la chaudi re sont idoines pour l utilisation de l eau potable b Dans la fa...
Page 3: ...VALVE 28 5 EXPLODED VIEWS 29 WARNING If the information in this manual is not followed exactly a fire of explosion may result causing property damage personal inju ry or loss of life Do not store or u...
Page 4: ...e following checks 1 Make sure that there are no liquids or inflammable materials in the immedia te vicinity of the boiler 2 Make sure that the electrical connec tions have been made correctly and tha...
Page 5: ...3 5 43 5 Maximum C H temperature C 85 85 F 185 185 Expasion vessel Water content l 8 8 USgal 2 1 2 1 Expasion vessel Pre charged bar 1 1 psi 14 5 14 5 C H setting range C 40 80 40 80 F 104 176 104 176...
Page 6: ...Water flow switch 15 Tridicator 16 Automatic by pass 17 D H W filter 18 C H return cock 19 C H flow cock 20 D H W cock 21 Gas cock 22 Aqua Guard Filter System Figure 3 KEY 1 Control panel 3 Combustio...
Page 7: ...s or local codes having jurisdiction Where an exhaust fan or any other air consuming appliance is installed in the same space as the boiler sufficient air openings must be available to provide fresh a...
Page 8: ...initiate a call for heat see user instructions verify red led Ignition lock out light is on after ignition boiler reset boiler by rotating the function knob to chimney sweep and stay at least one sec...
Page 9: ...8084811 complete with mounting instructions With the curve supplied in the kit the maximum horizontal length of the flue must not exceed 4 m 13 ft The diagrams in fig 6 illustrate a number of exam ple...
Page 10: ...Diaphragm Diaphragm Without Diaphragm None 86 3 4 87 5 3 44 diaphragm 87 5 3 44 diaphragm cod 6028623 cod 6028624 cod 6028624 L min 1 3 m L min 2 5 m L min 4 m L min 2 5 m 4 27 ft 8 2 ft 13 1 ft 8 2...
Page 11: ...ams in fig 9 a illustrate a num ber of examples of different types of sepa rate outlets 2 8 POSITIONING OF OUTLET TERMINALS fig 11 The outlet terminal must be flush with the wall and the inlet termina...
Page 12: ...inches KEY 1 Separate flue kit code 8089909 2a 90 elbow MF 2b Isolated 90 elbows MF 3a Extension L 1000 mm 39 4 inch 3b Insulated extension L 1000 mm 39 4 inch 3c Extension L 500 mm 19 7 inch 4 Outlet...
Page 13: ...n 900 mm 3 ft of a window or door that can be opened in any building of any non mechanical air supply inlet to any building or of any combustion air inlet of any other appliance h Underneath a veranda...
Page 14: ...nd two family dwellings a venting system that extends through any zone above that on which the connected appliance is located shall be provided with an enclosure having a fire resistance rating equal...
Page 15: ...poisoning 1 Align pipes and push them together as far as they will go to indent or at least 1 75 inches 2 Tighten gear clamp to a minimum torque of 40 in lbs and a maximum of 50 in lbs NOTE Some flue...
Page 16: ...all This applies to both combustible and non combustible walls 3 The system must be supported along its horizontal length at all elbow locations and joints every forty eight inches or less using strap...
Page 17: ...tible floor or ceiling The opening must be framed for the support since the support also serves as a firestop 5 The roof flashing can now be installed Where the vent passes through the roof a flashing...
Page 18: ...Install the Guy Band below the Rain Cap using the 10 24 screw and nut provided 2 Attach stainless steel or galvanized cable with a minimum rated capacity of 500 lbs 227 kgf to each of the four anchor...
Page 19: ...pe length and attach top support to pipe Leave 6 150 mm of pipe protruding from flashing so that rain cap may be installed and to allow for any adjustment to line up base tee pro perly 3 Fasten flashi...
Page 20: ...per ope ration after servicing Remove the three screws 9 locking the con trol panel in place and pull the panel forward until it can be tilted downward To access the components of the electrical panel...
Page 21: ...n electrode TRA Ignition transformer TS 100 C 212 F safety stat PA Water pressure switch FL Flowmeter TF Smokes stat OP Time programmer Nota The room stat or the programmable thermostat must be connec...
Page 22: ...ations described above be carried out by authorized technical staff 3 2 TEMPERATURE SENSOR Antifreeze system made up of the NTC hea ting sensor that activates when the water temperature reaches 6 C 43...
Page 23: ...al of the ignition transfor mer The electrode is earthed or very worn and needs to be substituted The control box is defective When there is a sudden voltage failure the bur ner shuts out immediately...
Page 24: ...eir local valves will be connected Connect micro switches or relay contacts on terminals 15 16 of the TA connector of the electronic card after removing the existing jumper fig 18 CR1 CR Connettore TA...
Page 25: ...5 SIGMA HONEYWELL VK 4105M SIEMENS VGU 50 gas valve fig 21 The gas valve is set at two pressure values maximum and minimum According to the type of gas burnt these correspond to the values given in Ta...
Page 26: ...djust maximum pressure using the nut 3 fig 22 a with a wrench to the maxi mum pressure value indicated in Table 4 7 Do not adjust minimum pressure until you have adjusted maximum pressure 8 Turn off t...
Page 27: ...sits every 6 months it is recommended to periodically inspected the intake and the exhaust terminal for debris or snow removed from blocking the termination Any dirt within the vent shall be removed w...
Page 28: ...tch is working and that the relative contact is in the rest position 2 Check whether connection tubes of smoke pressure switch are obstructed and if necessary clean away impurities or condensate 3 The...
Page 29: ...29 ENG 5 EXPLODED VIEWS VUES CLAT ES...
Page 30: ...1 Panneau c t gauche chambre combustion Combust chamber left hand side panel 16 6139773 Isolation arri re chambre de comb Combustion chamber rear insulation 17 6139792 Calorifuge lat ral chambre combu...
Page 31: ...plaques 16 plate heat exchanger kit 55 6281504 Vanne de d viat pression d eau Divertor valve 56 6119355 Bouchon pour groupe en Technyl Brass plug for hydraulic group 57 6226607 Ressort de fixation tu...
Page 32: ...310 Porte ant rieur chambre tanche Sealed chamber front panel 93 6001210 Regard de flamme Peephole 94 6287331 Jaquette Casing 95 2013302 Plaquette pour vis t le Fastener for self tapping screw 96 2004...
Page 33: ...onnecteur 90 Connector 90 6299994 Connecteur 4 bornes Lumberg 4 pole Lumberg cable connector 6299995 Connecteur 14 bornes Lumberg 14 pole Lumberg cable connect 6299996 Connecteur 6 bornes Stocko 6 pol...
Page 34: ...34 ENG...
Page 35: ...35 ENG...
Page 36: ...315 Oser Avenue Hauppauge NY 11788 Tel 631 694 1800 Fax 631 694 1832 www embassyind com...