Control the Elements 

 

 

 

 

 

 

Owner’s Manual – 

6200VSi / 6200VSx / 8200VSi / 8200VSx 

 

Summary of Contents for 6200VSi

Page 1: ...V9 14 Control the Elements Owner s Manual 6200VSi 6200VSx 8200VSi 8200VSx...

Page 2: ...ave questions please don t hesitate to contact your dealer or CellarPro directly We can be reached during normal business hours at 1 877 726 8496 You also may contact us anytime via email at info cell...

Page 3: ...3 V9 14 T a b l e o f C o n t e n t s I Specifications and Cut Sheets 4 II Installation Instructions 9 III Operating Instructions 15 IV Troubleshooting 25 V Limited Warranty 27...

Page 4: ...Cut Sheet Model Dimensions inches W x D x H Weight Running Compressor Amps 6200 8200VSi 16 1 x 29 3 x 21 9 incl drain 130 10 5A 6200 11 8A 8200 6200 8200VSi 16 1 x 33 1 x 21 9 incl rear duct hood dra...

Page 5: ...and the rear of the cooling unit require a minimum clearance of 8 inches These units also can be placed completely INSIDE or OUTSIDE the cellar when used in combination with our duct kits Ambient Env...

Page 6: ...face mounted fixtures are recommended over recessed lighting which can allow air to leak into the cellar It is important that all walls joints doors and windows electrical outlets and or switches pipe...

Page 7: ...he cooling unit to produce cold air In addition the cooling unit must be installed so that after its installation the condenser coils are accessible for periodic cleaning or replacing of the filter Th...

Page 8: ...el kit that can be installed remotely up to 10 feet from the cooling unit either inside or outside the cellar and a bottle probe 10 foot cord that can be plugged into the cooling unit Power Requiremen...

Page 9: ...note The cooling system is programmed with a 3 Minute Delay at Startup to protect its internal components Cut a hole in the wall that is 1 4 inch larger than the dimensions W x H of the cooling unit a...

Page 10: ...ove the cooling unit which is very heavy Do not place the cooling unit on unprotected bottle racks Tilt the cooling unit slightly backwards The rear of the cooling unit should be slightly lower than t...

Page 11: ...11 V9 14 6200 8200VS Installation Diagrams...

Page 12: ...the side brackets there are no mounting holes for the bottom mounting bracket in the case of the cooling unit Secure the top and bottom brackets to the side brackets with 4 1 4 20x5 8 bolts and lockw...

Page 13: ...sult the manufacturer for recommendations For duct runs greater than 50 equivalent feet the auxiliary fan option is required Ducted Installations Front Duct Kit 1 Ductwork must be attached to BOTH the...

Page 14: ...determine the total equivalent feet of a specific duct routing design or consult the manufacturer for recommendations 5 The High fan speed setting is required for long duct runs and as ambient temper...

Page 15: ...the time CellarPro cooling units are designed to maintain optimal temperatures for storing and aging fine wine CellarPro cooling units are not designed to maintain III Operating Instructions Summary K...

Page 16: ...t Point For example if the Minimum Set Point is 58 F and the Temperature Differential is 4 F the cooling unit will turn on when the temperature rises above 62 F inside the cellar and it will turn off...

Page 17: ...nd energy efficiency select the lowest fan speed that will maintain the desired cellar temperature High speed is recommended for initial cellar pull down extreme temperature conditions and ducted inst...

Page 18: ...bottle probe sold separately to control the cellar by liquid temperature rather than air temperature inside the cellar Disconnecting the probe will automatically return the control to air temperature...

Page 19: ...displayed RST will blink three times to indicate confirmation Set Button The cooling unit is factory preset with a Minimum Set Point of 58 F and a Temperature Differential of 4 This means that the co...

Page 20: ...on when the cooling unit is in Energy Saver mode In Energy Saver mode the Minimum Set Point increases 4 F and the Temperature Differential is unchanged Quick Chill Button To activate the Quick Chill...

Page 21: ...l the unit reaches set point This mode is useful after loading warm bottles in the cabinet The cooling unit has a factory default defrost cycle that initiates every 16 hours for 20 minutes When the co...

Page 22: ...ng is 0 6 TEMPERATURE DIFFERENTIAL The factory preset for this setting is 4 This setting determines the Temperature Differential and therefore the temperature at which the cooling unit will cycle on T...

Page 23: ...atures that are too hot The compressor and condenser fan will turn off until the condenser temperature falls below 120 F Maintenance The condenser coils at the back of the cooling unit will collect du...

Page 24: ...et has dropped below the alarm temperature setting Call CellarPro at 877 726 8496 Check if the cellar has a leak Check if door was left open Lower the ambient temperatures Check for appropriate instal...

Page 25: ...age temperatures inside cellars with adequate insulation up to 2200 cubic feet depending on the cooling unit thermal load and desired cellar temperature Hot weather conditions insufficient ventilation...

Page 26: ...lso make sure that there aren t any obstructions to the intake and or exhaust vents If your wine cabinet has a grill remove the grill and or any other obstructions above top vent or behind back vent t...

Page 27: ...ry or an authorized dealer Damage caused by others or by any cause beyond the control of CellarPro shall not be considered defects in material or workmanship and are not covered by the warranty The li...