4  ON BOARD RESOURCES 

4.1 POWER 

SUPPLY 

The three position slide switch (SW6) operates in accordance with the settings given in Table 8. 
The Power Indicator LED (red) illuminates when power is applied to the evaluation board 
through any of the methods. 
 

Table 8 – EVB3 Power Switch Settings 

Power 

Switch 

Position 

VCC Power 

Supply Value 

Comments 

Switch 

Position 

1 VREG 

VUSB: 5.0 V  

DC Jack:  5.0 – 9.0 V 

In this position the evaluation board and module 
are either powered from the USB interface or 
through the DC Jack from an external supply. 

 

2 VBAT 

3.0 

In this position the evaluation board and module 
are powered from the two 1.5 V Type AA batteries. 

3  VREG + J4 

ZIC2410-EVB3:  5 V 

ZICM2410: 2.1 – 3.0V 

In this position the evaluation board is powered via 
either the USB interface or through the DC Jack.  
The ZICM2410 module is powered externally via 
the J4 header.  See the 

“ZICM2410-EVB3 

Evaluation Board Hardware Reference Guide”

 

for further details. 

NOTE #1:  

At power-on, the evaluation board preforms an initialization routine (approximately 1 second) during which 

all the LEDs (LED1 through LED4) are illuminated.  Once the initialization routine has completed the LEDs are turned 
off. 
 

NOTE #2:

  If batteries are loaded into the holder and the board also has power applied via the USB or DC Jack, and the 

Power Switch is toggled between the VBAT and either of the VREG postions the device may get stuck in the 
initialization routine.  If this occurs, simply press the RESETB button. 

 

4.2 RESET 

The 

ZICM2410-EVB3

, by default, has the switch labeled 

‘RESETB’

 (SW5) connected to the 

‘RESET#’

 pin of the 

ZICM2410

 module.  When pressed, the 

ZIC2410

 will be reset.  Using the 

isolation DIP switches (U203:2), SW5 can be disconnected and external circuitry added. 
 

 

Figure 3 – Photo, RESETB Push Button (SW5)  

 

4.3 ISP 

SWITCH 

The 2-position slide switch (SW7) controls the mode of operation, as shown in Figure 4.  The 

ZIC2410

 can be placed into either 

‘ISP’

 or 

‘NORMAL’

 mode.  When placed into ISP mode, the 

ZIC2410

 is configured for the programming of the internal Flash memory (i.e. a firmware 

upgrade).  In order to enter ISP mode, the slider switch must be set to 

‘ISP’

 and then power 

applied to the device (alternatively, if power has already been applied the 

‘RESETB’

 pushbutton 

Summary of Contents for ZICM2410-EVB3

Page 1: ...ZIC2410 Series MeshConnect ZICM2410 EVB3 Evaluation Board Hardware Reference Guide 0007 05 08 03 001 Rev C...

Page 2: ...PTION 6 3 2 ZICM2410P0 MODULE CONNECTION 7 3 3 ZICM2410P2 MODULE CONNECTION 10 4 ON BOARD RESOURCES 13 4 1 POWER SUPPLY 13 4 2 RESET 13 4 3 ISP SWITCH 13 4 4 POWER HEADER J4 14 4 5 LEDS 14 4 6 PUSHBUT...

Page 3: ...solution for IEEE 802 15 4 wireless applications 1 1 PART DEFINITIONS ZIC2410QN48 CEL MeshConnect single chip IEEE 802 15 4 transceiver ZICM2410P0 CEL MeshConnect IEEE 802 15 4 module ZICM2410P2 CEL M...

Page 4: ...e ESD The ZICM2410 EVB3 is a PC interface board to which the ZICM2410P0 ZICM2410P2 module has been mounted A ZICM2410 EVB3 can be used to interface PC applications with the module in order to program...

Page 5: ...d as external interrupts to the 8051 microcontroller Battery Holders Holder for 2 ea 1 5 Volt Type AA Batteries DC JACK Input for a 5 0 9 0 Volt DC Power Supply POWER Switch This three position slide...

Page 6: ...odule is the primary active component device under test of the ZICM2410 EVB3 evaluation board Figure 2 shows the ZICM2410P0 ZICM2410P2 modules whose major components are as follows ZIC2410QN48 Power A...

Page 7: ...d to Ground PAD 4 GND0 Connected to Ground 13 5 MS0 Connected to Ground 6 NC2 No Connection PAD 7 GND20 Connected to Ground PAD 8 GND12 Connected to Ground PAD 9 GND13 Connected to Ground PAD 10 GND17...

Page 8: ...SPI Bus on EVB3 30 29 4 ON P3_4 GPIO P3 4 When U205 4 ON Connected to SPI Bus on EVB3 30 GND10 Connected to Ground 31 31 5 ON P3_3 GPIO P3 3 When U205 5 ON Connected to SW4 on EVB3 32 32 6 ON P3_2 GPI...

Page 9: ...ON Connected to LED2 on EVB3 42 43 6 ON P0_1 GPIO P0 1 When U203 6 ON Connected to LED3 on EVB3 43 44 5 ON P0_0 GPIO P0 0 When U203 5 ON Connected to I2S Bus on EVB3 19 45 4 ON DVDD_1_5 1 5 Volt Regu...

Page 10: ...nnected to Ground PAD 4 GND0 Connected to Ground 13 5 MS0 Connected to Ground 6 NC2 No Connection PAD 7 GND20 Connected to Ground PAD 8 GND12 Connected to Ground PAD 9 GND13 Connected to Ground PAD 10...

Page 11: ...SPI Bus on EVB3 30 29 4 ON P3_4 GPIO P3 4 When U205 4 ON Connected to SPI Bus on EVB3 30 GND10 Connected to Ground 31 31 5 ON P3_3 GPIO P3 3 When U205 5 ON Connected to SW4 on EVB3 32 32 6 ON P3_2 GPI...

Page 12: ...ON Connected to LED2 on EVB3 42 43 6 ON P0_1 GPIO P0 1 When U203 6 ON Connected to LED3 on EVB3 43 44 5 ON P0_0 GPIO P0 0 When U203 5 ON Connected to I2S Bus on EVB3 19 45 4 ON DVDD_1_5 1 5 Volt Regu...

Page 13: ...evaluation board preforms an initialization routine approximately 1 second during which all the LEDs LED1 through LED4 are illuminated Once the initialization routine has completed the LEDs are turned...

Page 14: ...llows the monitoring of the module s supply line through Pin 4 SENSE Table 9 Power Header J4 Pin Out Pin 1 Pin 2 Pin 3 Pin 4 GND SENSE GND Module Supply VCC Module Supply VCC Module SENSE 4 5 LEDs Fig...

Page 15: ...external SPI Flash memory connected to the Serial Peripheral Interface SPI of the ZIC2410 The external memory is required when performing Over the Air programming Using the isolation DIP switches the...

Page 16: ...it 6 8 P0_7 GPIO Port 0 Bit 7 J9 Current Monitor 2 pin connector 1 VCC_MODULE When this jumper is removed a DC current meter can be inserted to monitor the current of the evaluation board 2 VCC J11 GP...

Page 17: ...ev C Document No 0007 05 08 03 001 Page 17 of 19 5 REVISION HISTORY Revision Date Description A 11Jun09 Released B 18Sep09 Updated to support the use of a ZICM2410P2 module on the EVB3 evaluation boar...

Page 18: ...9 NC 20 NC 21 NC 22 NC 23 CTS 24 RTS 25 RXD 26 TXD 27 DSR 28 DTR U10 CP2102 C25 1uF 1 CS 2 SO 3 WP 4 GND 5 SI 6 SCK 7 HOLD 8 VCC U8 AT25FS010N JMP1 929955 06 JMP SCREW1 4 40 X 5 16 SCREW2 4 40 X 5 16...

Page 19: ...rence Guide Rev C Document No 0007 05 08 03 001 Page 19 of 19 APPENDIX 2 BILL OF MATERIALS ZICM2410 EVB3 CEL Doc 0007 01 02 03 001 Issue ES X3 This document is subject to revision without notification...

Reviews: