![CEL MeshConnect EM357 Series Datasheet Download Page 13](http://html.mh-extra.com/html/cel/meshconnect-em357-series/meshconnect-em357-series_datasheet_2579060013.webp)
MeshConnect™
EM357 Mini Modules
Page 13
AGENCY CERTIFICATIONS
(Continued)
Software Compliance
The ZICM357SP2 requires software restrictions to meet agency certification requirements. These restrictions have been
implemented in the sample application included with the software development kit.
If a customer is not starting with CEL's software development kit, they must implement these output power restrictions to
use the ZICM357SP2 FCC or IC certification:
Certification
RF Channel
Valid TX
Power Steps
Typical Max
Output Power
ZICM357SP0-1
FCC/IC
11 - 25
-43 to 8
8 dBm
26
-43 to 0
1 dBm
ETSI
11 - 26
-43 to 8
8 dBm
ZICM357SP2-1
FCC/IC
11 - 24
-43 to -2
20 dBm
25
-43 to -6
17 dBm
26
-43 to -26
-3 dBm
ZICM357SP2-1C
FCC/IC
11 - 24
-43 to -2
20 dBm
25
-43 to -12
9 dBm
26
-43 to -38
-5 dBm
Note:
For the ZICM357SP2, Power mode 2 with Power Setting "-2" is the maximum setting allowed for FCC compliance.