CEL-MAR DNB-200 User Manual Download Page 3

1. GENERAL INFORMATION

Thank you for your purchase of CEL-MAR Company product. This product has been completely tested and is covered by two year 

warranty on parts and operation from date of sale.

If any questions or problems arise during installation or use of this product, please do not hesitate to contact Technical Support at +48

41 362-12-46 or e-mail [email protected].

1.1. WARRANTED INFORMATION 

CEL-MAR Company

  gives the two year guarantee on the

  DNB-200 splitter.

   In case of being damaged it will be repair or the 

damaged component will be replace. The warranty does not cover damage caused from improper use, materials consumption or any 

unauthorized changes. If the product does not function (is damaged), or not operate in accordance with the instructions, will be 

repaired.
All warranty and no warranty repairs must be returned with paid transport and insuring to the 

CEL-MAR Company.

CEL-MAR Company 

under no circumstances won't be responsible for ensuing damage from improper using the product or as a result  

of random causes: the lightning discharge, the flood, the fire and the like.

CEL-MAR Company

 is not be held responsible for damages and loss including: loss of profits, loss of data, pecuniary losses ensuing 

from using or the impossibility of using this product.
In specific cases

 CEL-MAR Company

 discontinue all warranties and in particular do not follow the user manual and do not accept  

terms of warranty by the user.

1.2. GENERAL CONDITIONS FOR SAFE USE

The device should be installed in a safe and stable places, the powering cable should be arranged so as not to be exposed to  

trampling, attaching, or pulling out of the circuit. 

Do not put device on the wet surface.

Do not connect devices for nondescript powering sources,

Do not damage or crush powering wires.

Do not make connection with wet hands.

Do not adapt, open or make holes in casings of the device!

Do not immerse device in water or no other liquid.

Do not put the fire opened on device sources: candles, an oil lamps and the like.

1.3. ENVIRONMENTAL PRESERVATION

This sign on the device inform about putting expended device with other waste materials. Device should send to the 

recycling. (In accordance with the act about the Electronic Appliance Expended from day 29 of July 2005)

1.4. SERVICE AND MAINTENANCE

It is recommended to check the status of modular sockets and the sensors connecting cables, to eliminate the influence of mechanical  

damage on the quality of measurement . 

Technical support is available at 48 41 362-12-46 in 8.00-16.00, from Monday to Friday or e-mail [email protected].

2. SOLUTIONS

Splitter DNB-200 is used to for connection of digital sensors as: DTS-103, DTS-107 to remote multi-point measurement temperature 

system in:

rooms with structured cabling, 

automation cubicles,

data communication  cubicles,

devices,

and outside temperature via the serial bus 1-WIRE.

Application of 1-Wire bus enables:

the cooperation of many sensors connected to the same data lines,

the deployment of sensors in various locations up to 260m,

powering the sensors from the bus,

guarantee the correct transmission of measurement data secure checksum CRC

3. SPECIFICATIONS

Parameters 

Data

Casing material

Polystyrene

Operating temperature

from -30°C to +70°C

Degree of protection

IP20

Dimensions 

50,2 x 40,2 x 20,6 mm

Weight

0,05 kg

Storage and transport

outdoor temperature

-30 ÷ +70°C

Relative air humidity

5 ÷ 95% - noncondensing

3

DNB-200

Reviews: