background image

12. PARAMETERS

Parameters 

Data

Parameters of Temperature Sensor

Measuring range of temperature

-30°C ... +60°C

1-WIRE Transducer

DS18B20

Temperature measurement range by the transmitter

-55°C … 125°C

Measuring accuracy of temperature  transducer

+/-0,5°C in the scope -10°C...+85°C

Temperature  transducer resolution

12 bits (0,06°C)

Operating temperature

-30°C ... +60°C

Parameters of Humidity Sensor

Measuring range of relative humidity

0%  ... 100% RH

Measuring accuracy of relative humidity

+/-3,50% RH

Operating temperature

-30°C ... +60°C

Parameters of Atmospheric Pressure Sensor

Measuring range of atmospheric pressure

150 hPa  ... 1150 hPa

Measuring accuracy of atmospheric pressure

+/-15 hPa

Operating temperature

-30°C ... +60°C

Parameters of Sunlight Sensor

Measuring range of sunlight

0%  ... 100% 

Measuring accuracy of sunlight

---

Operating temperature

-30°C ... +60°C

Parameters of Lighting Sensor

Measuring range of lighting

0%  ... 100% 

Measuring accuracy of lighting

---

Operating temperature

-30°C ... +60°C

General Parameters

Supply voltage

From 1-WIRE bus VDD=5VDC

Max. power

10-20mW

Protection from reverse power polarization

YES

Warning! on reverse power on is shorted VDD to GND

Bus cabling

Recommended UTP 4x2x0.5 AWG24 twisted cable

Cover

Operating temperature

from -30°C to +60°C

Material

Polystyrene

Protection degree

IP65

Dimensions

88,4 x 66,4 x 42,2 mm

Weight

0,05 kg

Storing and Transportation

Storage temperature

-40°C ÷ +70°C

Humidity

5 ÷ 95% - non-condensing

11

DES-215

Summary of Contents for DES-215

Page 1: ...User manual DES 215 Digital environmental parameters sensor 1 io des 215 en v 1 04 DES 215 Copyright 2001 2015 CEL MAR sp j ...

Page 2: ...E DEVICES 4 4 VIEW OF TEMPERATURE OR RELATIVE HUMIDITY OR ATMOSPHERIC PRESSURE SENSOR 4 5 VIEW OF TEMPERATURE AND RELATIVE HUMIDITY AND ATMOSPHERIC PRESSURE SENSOR 5 6 VIEW OF LIGHTING SUNLIGHT SENSOR 6 7 CONNECTION OF 1 WIRE LINE TO STRAIGHT THROUGH SENSOR 7 8 CONNECTION OF 1 WIRE LINE TO END LEFT SENSOR 7 9 CONNECTION OF 1 WIRE LINE TO END RIGHT SENSOR 8 10 EXAMPLES CONNECTIONS 9 11 VERSIONS 10 ...

Page 3: ... Do not adapt open or make holes in casings of the device Do not immerse device in water or no other liquid Do not put the fire opened on device sources candles an oil lamps and the like 1 3 CE LABEL CE symbol on organizing the company CEL MAR a conformity of the device to the directive of the electromagnetic EMC 89 336 EWG Electromagnetic Compatibility Directive The declaration of the agreement i...

Page 4: ...Bus Splitter DNB 215 Passive 1 WIRE Bus Splitter DNB 200 Passive 1 WIRE Bus Splitter other 1 WIRE sensors eg DTS RJ45 DTS 103 DTS 107 DES 200 DES 215 DES 300 4 VIEW OF TEMPERATURE OR RELATIVE HUMIDITY OR ATMOSPHERIC PRESSURE SENSOR 4 DES 215 Lc 53mm d 6mm PG 7 88 5mm 66 5mm 30mm 42 5mm 15mm PG 7 R PG 7 L PG 7 R PG 7 L Stainless steel or brass protection PG 7 Stainless steel or brass protection for...

Page 5: ...RELATIVE HUMIDITY AND ATMOSPHERIC PRESSURE SENSOR 5 DES 215 88 5mm 66 5mm Lc 53mm 30mm d 6mm PG 7 R 42 5mm 15mm PG 7 L PG 7 R PG 7 L Stainless steel or brass protection d 6mm Lc 53mm PG 7 PG 7 Stainless steel or brass protection ...

Page 6: ...6 VIEW OF LIGHTING SUNLIGHT SENSOR 6 DES 215 88 5mm 66 5mm 30mm 42 5mm 15mm PG 7 R PG 7 L PG 7 R PG 7 L photoelectric element ...

Page 7: ...us made by UTP 4x2x0 5 cable Cat 5 to end left sensor 7 DES 215 LINE B 1 W LINE B GND VDD 1 W LINE B RETURN GND COM 1 W LINE A RETURN GND COM 1 W LINE A GND VDD 1W R COM GND R LINE A 1W R COM GND R Connecting the other wires Connecting the other wires 1 W GND VDD 1 W GND VDD 1 W LINE B GND VDD 1 W LINE B RETURN GND COM 1 W LINE A RETURN GND COM 1 W LINE A GND VDD LINE A 1W R COM GND R Connecting t...

Page 8: ...R Example connection of 1 WIRE bus made by UTP 4x2x0 5 cable Cat 5 to end right sensor 8 DES 215 Connecting the other wires LINE B 1 W LINE B GND VDD 1 W LINE B RETURN GND COM 1 W LINE A RETURN GND COM 1 W LINE A GND VDD 1W R COM GND R 1 W GND VDD ...

Page 9: ... Vss Vss Unused wires of twisted pair connect together and connect the electrical installation PE 230V V N V 10 24V ADA 401WP DES 215 T F STRAIGHT THROUGH DES 215 TH F STRAIGHT THROUGH RS485 2W do 1200m UTP 4x2x0 5 cable 1 W LINE B GND VDD 1 W LINE B RETURN COM GND 1 W LINE A GND VDD 1 W LINE A RETURN GND COM 1 W LINE B GND VDD 1 W LINE B RETURN COM GND 1 W LINE A GND VDD 1 W LINE A RETURN GND COM...

Page 10: ...ssure sensors 6 Length of measuring part Lc mm for lighting sunlight sensor 0 50 100 150 200 for temperature relative humidity atmospheric pressure sensors 50 Material covers the measuring unit for lighting sunlight sensor 0 brass tube placed in the gland 1 stainless steel 1 4541 tube placed in the gland 2 Connection type Straight through F End right ER End left EL Order example Product symbol DES...

Page 11: ... Measuring accuracy of atmospheric pressure 15 hPa Operating temperature 30 C 60 C Parameters of Sunlight Sensor Measuring range of sunlight 0 100 Measuring accuracy of sunlight Operating temperature 30 C 60 C Parameters of Lighting Sensor Measuring range of lighting 0 100 Measuring accuracy of lighting Operating temperature 30 C 60 C General Parameters Supply voltage From 1 WIRE bus VDD 5VDC Max ...

Page 12: ...ic Converters 1 Wire ETHERNET Wi Fi digital sensors as temperature humidity pressure illumination power supply Please express your opinion by e mail or phone on this product and advise us how we can satisfy you present and future of expecting CEL MAR sp j Computers Science and Electronic Factory str Sciegiennego 219C 25 116 Kielce Poland Tel 48 41 362 12 46 Tel fax 48 41 361 07 70 Web http www cel...