![CEL-MAR ADA-4040PC6 User Manual Download Page 13](http://html1.mh-extra.com/html/cel-mar/ada-4040pc6/ada-4040pc6_user-manual_2579191013.webp)
Address
3X
Registers
Address
Registers
description
Attribute
Value
VLW | TOTAL CUMULATIVE WATER DISTANCE DWORD = 0x05F5 FC88
WORD LO = FC88; BYTE HI = 0xFC; BYTE LO = 0x88
DW=1000
30036
35
VLW | TOTAL CUMULATIVE WATER DISTANCE DWORD = 0x05F5 FC88
WORD HI = 0x05F5; BYTE HI = 0x05; BYTE LO = 0xF5
R
16-bit register
U32 HI
DW=1000
30037
36
VLW | DISTANCE SINCE RESET: 100007.048,N
VLW | DISTANCE SINCE RESET DWORD = 0x05F5 FC88
WORD LO = FC88; BYTE HI = 0xFC; BYTE LO = 0x88
R
16-bit register
U32 LO
30038
37
VLW | DISTANCE SINCE RESET DWORD = 0x05F5 FC88
WORD HI = 0x05F5; BYTE HI = 0x05; BYTE LO = 0xF5
R
16-bit register
U32 HI
30039
38
VLW | NAUTICAL MILES: NN
VLW | NAUTICAL MILES WORD = 0x4E4E
BYTE HI = 0x4E = N(ASCII) CUMULATIVE DISTANCE, NAUTICAL MILES
BYTE LO = 0x4E = N(ASCII) DISTANCE SINCE RESET, NAUTICAL MILES
R
16-bit register
U16
CH[2]
30040
39
MWV
MWV | WIND ANGLE
R
16-bit register
U16
DW=10
30041
40
MWV | WIND ANGLE REFERENCE : R = Relative, T = Theoretical
BYTE HI = 0x00
BYTE LO = 0x52 (ASCII: R) lub 0x54 (ASCII: T)
R
16-bit register
U16
CH[2]
30042
41
MWV | WIND SPEED
R
16-bit register
U16
DW=10
30043
42
MWV | WIND SPEED UNIT & DATA STATUS
BYTE HI = K – km/h, M – m/s, N – knots (ASCII) | SPEED UNIT
BYTE LO = A - Data Valid, V - Data invalid (ASCII) | DATA STATUS
R
16-bit register
U16
CH[2]
30044
43
XDR
XDR | SENSOR1 – VALUE CD AB
INT32 : CD
R
32-bit register
I32
DW=1000
30045
44
XDR | SENSOR1 – VALUE CD AB
INT32 : AB
R
32-bit register
I32
DW=1000
30046
45
XDR | SENSOR1 – VALUE TYPE, VALUE UNIT
BYTE HI = C–Temperature, H–Humidity, U–Voltage (ASCII) | VALUE TYPE
BYTE LO = C–°C, H–%RH, V–Volts (ASCII) | VALUE UNIT
R
16-bit register
U16
CH[2]
30047
46
XDR | SENSOR1 – IDENTIFIER
BYTE HI = A (ASCII) | ID CHAR1
BYTE LO = 1 (ASCII) | ID CHAR2
R
16-bit register
U16
CH[2]
30048
47
XDR | SENSOR2 – VALUE CD AB
INT32 : CD
R
32-bit register
I32
DW=1000
30049
48
XDR | SENSOR2 – VALUE CD AB
INT32 : AB
R
32-bit register
I32
DW=1000
30050
49
XDR | SENSOR2 – VALUE TYPE, VALUE UNIT
BYTE HI = C–Temperature, H–Humidity, U–Voltage (ASCII) | VALUE TYPE
BYTE LO = C–°C, H–%RH, V–Volts (ASCII) | VALUE UNIT
R
16-bit register
U16
CH[2]
30051
50
XDR | SENSOR2 – IDENTIFIER
BYTE HI = A (ASCII) | ID CHAR1
BYTE LO = 2 (ASCII) | ID CHAR2
R
16-bit register
U16
CH[2]
30052
51
XDR | SENSOR3 – VALUE CD AB
INT32 : CD
R
32-bit register
I32
DW=1000
30053
52
XDR | SENSOR3 – VALUE CD AB
INT32 : AB
R
32-bit register
I32
DW=1000
30054
53
XDR | SENSOR3 – VALUE TYPE, VALUE UNIT
BYTE HI = C–Temperature, H–Humidity, U–Voltage (ASCII) | VALUE TYPE
R
16-bit register
U16
13
ADA-4040PC6