4. Installation
4.1. Electrical connections
Installation of this project involves a hazard of electric shocks. We strongly
recommend you contract a professional installer. Incorrect installation places
you in danger and may irreversibly damage the product and the equipment
connected to it.
For reasons of safety and compliancewith the NF C15-100 standard, the
box must be installed
• over 3m50 from the edge of the pool. This distance includes cable deviations
around obstacles. If the box is installed behind a wall, this will then
be the distance required to complete the loop and connect to the box.
• or in an underground space immediately next to the swimming pool. In this
case the space must be accessible via a hatch which requires a tool to open it.
The box is resistant to splashing but must not be placed in a place that may become flooded. The
box must be placed on a flat and stable surface and attached to the wall using the screws
and wall plugs supplied.
Electrical connection is facilitated by factory-fitting of a 3x2.5mm² cable.
www.c-
cei.fr