PROGRAMMING CONTINUED… 

 
 
 

3.06

 

If the telephone must dial a 

PBX or other access number

 to begin a call, 

enter

 

# 1 8 followed by the desired

 

number.   

If this is not a desired feature, please 

proceed to section 3.06.

  

This PBX/Access number may range from 1-11 digits.  

When the CALL button is pressed the telephone will automatically dial the 
PBX/Access number first, followed by an approximate one (1) second pause, 
and then dial the auto-dial number (programmed in the next section-3.06).  A 
“1” must be entered under Digit 8 in section 3.08 in order to activate this 
feature. 

 
 

EXAMPLE: 

Enter 

# 1 8

 9.  This will cause the phone to automatically dial the 

number “9”, when the CALL button is pressed.  This will be 
followed by an approximate one (1) second pause and then the 
auto-dial number will be released. 

 
 

#18 __  __  __  __  __  __  __  __  __  __  __ 
 
 
 
 

   3.07

  Enter #19 followed by the desired auto-dial number

.  When the phone   is in 

   

operation and the 

RED Emergency Button

 is pressed, this auto-dial 

 

   

number will automatically dial out.  This number may be up to eleven (11) 

   

digits in length.  To Program a 

Second Number auto-dial on the RED  

   

Emergency Button, Enter # 0 1 followed by the desired number.   

 
 
 

#19  ___   ___   ___   ___   ___   ___   ___   ___   ___   ___   ___ 
#01  ___   ___   ___   ___   ___   ___   ___   ___   ___   ___   ___  
         (location #01 Second Number Dial for the 

RED Button

 
 
 

Example:

  Enter 

# 1 9

 5 5 5 1 2 1 2.  This will program the phone to automatically 

dial the number 555-1212, whenever the 

RED Button

 is pressed.  Enter 

# 0 1

 5 8 

7 5 4 3 0.  This will program the phone to automatically dial number 587-5430 if 
number 555-1212 does not answer.  

Summary of Contents for WPP-531-D2-ADA-VA-R-SB24VDC

Page 1: ...E WITH OPTIONAL STEADY BURNING BLUE LIGHT FEATURE SECOND NUMBER AUTO DIAL VOICE ANNOUNCEMENT EQUIPPED WITH SPK1 07UNVLr3 FIRMWARE RED HOUSING EMERGENCY BUTTON Serving the Telephone Industry Since 1930 Communication Equipment 519 West South Park Street Engineering Company Okeechobee FL 34972 Voice 863 357 0798 Fax 863 357 0006 ...

Page 2: ...ing CEECO for assistance MODEL NUMBER MODEL WPP 531 D2 ADA VA R SB24VDC EQUIPPED WITH SPK1 07UNVLr3 FIRMWARE SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have this information available when calling for technical support CEECO Communication Equipment Engineering Company 519 West South Park Street Okeechobee FL 34972 863 357 0798 Voice 863 357 0006 Fax ...

Page 3: ... 4 3 0 PROGRAMMING 5 PROGRAMMING CONTINUED 6 PROGRAMMING CONTINUED 7 PROGRAMMING CONTINUED 8 4 0 TESTING OPERATION 9 5 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 10 INSTALLATION CONTINUED 11 6 0 SPECIFICATIONS 12 7 0 PARTS LIST 13 8 0 FCC NOTICE 14 9 0 REPAIR AND RETURN INFORMATION 15 10 0 WARRANTY POLICY 16 11 0 PROGRAMMING JUMPER DIAGRAM 17 ...

Page 4: ...onal blue steady burning light which operates on 24 VDC to give a visual locator of the telephone Instead of a hookswitch and handset the telephone has a Press To Start Press To Stop CALL button for the initiation and termination of phone calls A second number auto dial feature is included which allows the phone to be programmed to automatically dial a second number if the first programmed number ...

Page 5: ...o the phone NOTE Be sure to avoid contacting the printed circuit boards with metal objects as this may cause damage to the telephone 3 02 Connect the telephone line cord to a working telephone line 3 03 Locate the two mini jumpers on the large main Printed Circuit Board and place them in the ON position as depicted on the last page of this manual 3 04 Press the CALL button and wait for dial tone t...

Page 6: ...en the CALL button is pressed This will be followed by an approximate one 1 second pause and then the auto dial number will be released 18 __ __ __ __ __ __ __ __ __ __ __ 3 07 Enter 19 followed by the desired auto dial number When the phone is in operation and the RED Emergency Button is pressed this auto dial number will automatically dial out This number may be up to eleven 11 digits in length ...

Page 7: ...0 No Conversation Time Out 1 9 Minutes Conversation Time Out the call will automatically be terminated after the selected number of minutes Digit 4 0 Always 0 for this model Digit 5 0 Always 0 for this model Digit 6 0 Disable Second Number Dialing and ADA feature 1 9 Activate Second Number Dialing number of rings before retry and ADA feature Digit 7 0 Always 0 for this model Digit 8 PBX Access see...

Page 8: ...ed on the last page of this manual 3 10 Voice Announcement To record the voice announcement press the RED Button and the phone will dial the preprogrammed number in location 19 It may be easier to use another working number to do this other than 911 In such a case move the jumpers to enter the programming mode press the button enter only 19 followed by the working number and then hang up and move ...

Page 9: ...recording of 10 seconds or less was prerecorded A normal speakerphone conversation should take place Action If the first programmed number did not answer the second programmed number for the RED button should automatically dial out The dialing for the two programmed numbers should continue back and forth until one of them is answered Reaction Once answered the call should continue as normal Action...

Page 10: ...tools and test equipment CEECO Security Tool 301 064 Flat blade or Phillips head screw driver Wire Strippers 5 02 Using a 301 064 security tool sold separately loosen and remove the four 4 security screws Separate the faceplate assembly from the weatherproof housing by pulling the faceplate forward 5 03 Run the inside station wire into the enclosure and terminate on the RJ11C modular jack inside a...

Page 11: ...hieved and that proper conduit routing is followed Be certain to seal any open gaps on housing when wiring is completed in order to maintain the weatherproof integrity Water can follow wires into openings if not properly sealed Simple silicone sealer is normally sufficient 5 06 Plug the modular line cord from the faceplate assembly into the RJ11C terminal block Dress the line cord away from the se...

Page 12: ...P CURRENT 33mA minimum 80mA maximum IMPEDANCE 600 ohms SIGNALING DTMF 70ms tone 55 ms spacing OUTPUT 4 0dbm to 6 0dbm RINGER EQUIVALENCY 0 4A ENVIRONMENTAL Temperature 0 C to 50 C Humidity 20 90 non condensating PROGRAMMING Via DTMF keypad or remotely thru phone line WEIGHT Approximately 16 Pounds DIMENSIONS 9 Wide x 13 High x 8 5 Deep TYPE JACK RJ11C FCC REGISTRATION BW8USA 73021 MT E ...

Page 13: ...CREW 1 301 018 MODULAR LINE CORD 1 301 054UL MODULAR CONNECTOR RJ11C 1 700 008 KEYPAD CABLE 1 660 000 CEECO SPEAKER BOARD 1 705 110 CONNECTORIZED KEYPAD 2 6020 MOMENTARY PANEL SWITCH 1 14123 SPEAKER 1 14067 MICROPHONE 1 331 005 WEATHERPROOF HOUSING 1 331 024B STEADY BURNING BLUE LIGHT ACCESSORIES 1 301 064 SECURITY TOOL 1 331 016 SPRING LOADED DOOR OPTION ...

Page 14: ...hone Network through a registered jack provided by the Telephone Company in your area This jack is a modular outlet which you can order from your local telephone company 8 03 NOTIFICATION TO THE TELEPHONE COMPANY Before connecting this telephone the FCC requires that you notify your local telephone company business office The number is in the front of your phone book Tell them The line to which yo...

Page 15: ...to the defective unit This information must be inside the shipping container 9 02 DIRECT ALL INQUIRES TO CEECO Repair Department 519 West South Park Street Okeechobee FL 34972 863 357 0798 863 357 0006 9 03 NON WARRANTY REPAIR CEECO will repair equipment out of warranty for a set charge plus parts The customer must pay the shipping costs in both directions 9 04 RETURN FOR CREDIT Material may be re...

Page 16: ...replacement of any part found to be defective by CEECO Under no circumstances shall CEECO be liable for loss damage cost of repair or consequential damages of any kind which have been caused by neglect acts of God abuse or improper operation of equipment 10 02 PRINTED CIRCUIT BOARDS Printed circuit boards should not be repaired in the field If a unit is found to be faulty replace it with another u...

Page 17: ... DIAGRAM When programming is completed move the mini jumpers to the OFF position NOTE Do not leave the mini jumpers in the ON position this will decrease battery life Move the mini jumpers to the ON position BEFORE going off hook Locate the mini jumpers on the corner of the PCB ON OFF ON OFF ON OFF ...

Reviews: