5.0  INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 

 
 
 
 

*****WARNING***** 

 

A.

 

Never install telephone wiring during a lightning storm. 

 

 

B.  Never install telephone jacks in wet locations unless the jack 

 

      is specifically designed for wet locations. 

 

C.

 

Never touch uninsulated telephone wires or terminals unless 

      the telephone line has been disconnected at the network interface 

 

D.

 

Use caution when installing or modifying telephone lines. 

 

E.

 

DO NOT APPLY A/C POWER WHILE INSTALLING 
TELEPHONE. 

 
 
 
 
5.01  Recommended tools and test equipment: 

 

 

 

 

 

CEECO Security Tool, 301-064 

Flat blade or Phillips head screw driver 

 

 

 

 

 

 

 

Wire Strippers 

 

5.02  Using a 301-064 security tool (sold separately) loosen and remove the four (4) 

security screws.  Separate the faceplate assembly from the weatherproof housing 
by pulling the faceplate forward.  

 

5.03  Run the inside station wire into the enclosure and terminate on the RJ11C 

modular jack inside, as depicted on the following page.  The CEECO-provided 
jack must be used as it contains required over-voltage protection.   Mount the 
housing in the intended location using the four mounting holes provided.  There 
is a pole-mounting bracket available, which is sold separately. 

 

5.04  The use of a gas tube station protector is recommended.  The station ground 

should not exceed 50 ohms.  

Summary of Contents for WPP-531-D-ADA-STROBE

Page 1: ...31 D ADA STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE EQUIPPED WITH SPK1 07UNVLr1 FIRMWARE Serving the Telephone Industry Since 1930 Communication Equipment 519 West South Park Street En...

Page 2: ...alling CEECO for assistance MODEL NUMBER MODEL WPP 531 D ADA STROBE EQUIPPED WITH SPK1 07UNVLr1 FIRMWARE SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have this...

Page 3: ...MMING CONTINUED 6 PROGRAMMING CONTINUED 7 PROGRAMMING CONTINUED 8 4 0 TESTING OPERATION 8 TESTING OPERATION CONTINUED 9 5 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 10 INSTALLATION CONTINUED 11 6...

Page 4: ...nless steel panel and an aluminum weatherproof housing This telephone comes with an optional ADA feature red green LED giving visual feedback during periods of operation It also comes with an optional...

Page 5: ...the phone NOTE Be sure to avoid contacting the printed circuit boards with metal objects as this may cause damage to the telephone 3 02 Connect the telephone line cord to a working telephone line 3 0...

Page 6: ...to activate this feature EXAMPLE Enter 1 8 9 This will cause the phone to automatically dial the number 9 when the CALL button is pressed This will be followed by an approximate one 1 second pause and...

Page 7: ...Digit 1 1 Always 1 for this model Digit 2 0 No incoming calls allowed 1 Incoming calls allowed Digit 3 0 No conversation time out 1 9 Minute s conversation time out Digit 4 0 Always 0 for this model...

Page 8: ...onnected to a working telephone line press the CALL button located on the front of the telephone The LED will illuminate red at this time The blue strobe light will not function until AC power has bee...

Page 9: ...act If the automatic call disconnect feature does not work properly please repeat sections 3 02 3 03 3 04 3 08 and 3 10 only If trouble is still experienced please refer to section 11 02 4 05 If the p...

Page 10: ...test equipment CEECO Security Tool 301 064 Flat blade or Phillips head screw driver Wire Strippers 5 02 Using a 301 064 security tool sold separately loosen and remove the four 4 security screws Sepa...

Page 11: ...s will already be connected to the terminal strip The ground wire from the strobe light should be connected to any suitable earth ground Please refer to the wiring diagram on page 18 of this manual Be...

Page 12: ...ANCE 600 ohms SIGNALING DTMF 70ms tone 55 ms spacing OUTPUT 4 0dbm to 6 0dbm RINGER EQUIVALENCY 0 4A ENVIRONMENTAL Temperature 0 C to 50 C Humidity 20 90 non condensating PROGRAMMING Via DTMF keypad o...

Page 13: ...ON 4 331 006 OUTER COVER SECURITY SCREW 1 301 018 MODULAR LINE CORD 1 301 054UL MODULAR CONNECTOR RJ11C 1 700 008 KEYPAD CABLE 1 660 000 CEECO SPEAKER BOARD 1 705 110 CONNECTORIZED KEYPAD 2 6020 MOMEN...

Page 14: ...one Network through a registered jack provided by the Telephone Company in your area This jack is a modular outlet which you can order from your local telephone company 8 03 NOTIFICATION TO THE TELEPH...

Page 15: ...o the defective unit This information must be inside the shipping container 9 02 DIRECT ALL INQUIRES TO CEECO Repair Department 519 West South Park Street Okeechobee FL 34972 863 357 0798 863 357 0006...

Page 16: ...liable for loss damage cost of repair or consequential damages of any kind which have been caused by neglect acts of God abuse or improper operation of equipment 10 02 PRINTED CIRCUIT BOARDS Printed c...

Page 17: ...Issue 4 0 CEECO Communication Equipment Engineering Company PROPRIETARY 17...

Page 18: ...DIAGRAM When programming is completed move the mini jumpers to the OFF position NOTE Do not leave the mini jumpers in the ON position this will decrease battery life Move the mini jumpers to the ON po...

Reviews: