PROGRAMMING CONTINUED
LOCATION #00: (
OPTION TABLE
)
•
Be sure to record your selections here for future reference:
#00 0 __ __ 0 0 __ 0 __ 0 __
1 2 3 4 5 6 7 8 9 10
Digit 1:
0 Always
0
for this model.
Digit 2:
0
No
incoming calls allowed.
1
Incoming calls allowed (if equipped with ringer).
Digit 3:
0 No Conversation Time-Out.
1-9 Minute(s) Conversation Time-Out. (Automatically times & disconnects call)
Digit 4:
0
Always
0
for this model.
Digit 5:
0 Always
0
for this model.
Digit 6:
0 Deactivate ADA Feature
9 Activate ADA Feature (if equipped with visual call progress LED).
Digit 7:
0 Always
0
for this model.
Digit 8:
0
Do not
dial PBX access number stored in location #18.
1 Dial PBX access number stored in location #18.
Digit 9:
0
Always 0 for this model.
Digit 10:
0
No wink detect.
1-9 Length of the wink detect (1=50ms incremental to 450ms.
5
is recommended).
EXAMPLE
: Dial #00 0160090105 and the phone will be set as follows:
DIGIT 1 .. ALWAYS 0
DIGIT 2 .. INCOMING CALLS ALLOWED
DIGIT 3 .. 6 MINUTE CONVERSATION TIME OUT
DIGIT 4 .. ALWAYS 0
DIGIT 5 .. ALWAYS 0
DIGIT 6 .. ACTIVATE ADA FEATURE
DIGIT 7 .. ALWAYS 0
DIGIT 8 .. DIAL THE PBX ACCESS NUMBER FIRST
DIGIT 9 .. ALWAYS 0
DIGIT 10..250 ms wink detect.