ISSUE 4.0
CEECO
Communication Equipment & Engineering Company
PROPRIETARY
5
5.0
INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS
5.1
Using a 301-037 security tool (sold separately), loosen and remove the
security screw located in the bottom of the phone case.
5.2
The security tool is for a standard 5/32" button head screw generally used
on the framework of the phone booths.
5.3
Separate the telephone housing from the backplate by pulling the bottom
of the housing forward and lifting up on the housing.
5.4
The backplate is designed to be mounted on a flat vertical surface. Four
mounting holes are provided.
5.5
Run the inside station wire through the backplate and terminate on the
RJ11C terminal block inside.
5.6
The use of a gas tube station protector is recommended. The station
ground should not exceed 50 ohms.
5.7
Plug the modular line cord from the telephone into the RJ11C terminal
block.
5.8
Dress the line cable away from the locking screw and seat the case onto
the backplate. Secure the case by tightening the security screw.
*****WARNING*****
A.
Never install telephone wiring during a lightning storm.
B.
Never install telephone jacks in wet locations
unless the jack is specifically designed for wet
locations.
C.
Never touch uninsulated telephone wires or
terminals unless the telephone line has been
disconnected at the network interface.
D.
Use caution when installing or modifying telephone lines.