3.10

   When 

programming is finished

, return the 

mini-jumpers

 to the 

"OFF"

 

position. 

Hang up the phone

 by pressing the CALL button.  The phone is 

now 

ready for Testing/Operation

 
 

4.0 TESTING/OPERATION 

 

4.1

 

Connect the telephone to a working telephone line. 

 

4.2

 

To make a call, press the CALL button located on the front of the phone.  
When dial tone is received, the transmitter is muted and the phone waits 
for numbers to be dialed.  The LED will light RED at this time, and the 
preprogrammed number(s) will dial out on the line.   

 

4.3

 

The LED will flash red and green, while the call is ringing.  

 

4.4

 

When the called party answers the LED will turn GREEN after a 
maximum of four seconds, provided the ADA feature was activated (see 
section 3.7 Digit 6).  Otherwise, the LED will remain RED during off-
hook periods.  A normal speakerphone conversation should be allowed.  

 

4.5

 

When the call is complete, press the CALL button again to hang up.  The 
LED will go out and the call will be terminated. 

 

4.6

 

If the user does not press the CALL button when he or she is done, the 
phone will hang up after detecting a wink back from the far end, or when 
the selected time-out period (see section 3.7 Digit 3) expires.   

 

4.7

 

Place a call into the phone.  If the phone was programmed to allow 
incoming calls, answer the phone and the microphone should activate 
within approximately three (3) seconds.  A normal speakerphone 
conversation should follow.  If the phone was programmed not to allow 
incoming calls, the microphone will not activate.   

 

 

5.0  RECOMMENDED TOOLS AND TEST EQUIPMENT 

 
      

DTMF Test Set 

      

Volt/Ohm Meter 

      

3/8" Nut Driver 

      

5/16" Nut Driver 

      

Flat Blade Screw Driver 

     

Security Tool CEECO P/N 301-064

 

 

6.0  INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 

       

Summary of Contents for SSP-571-D

Page 1: ...D FORMERLY MODEL SSP 579 D HANDS FREE PANEL TELEPHONE EQUIPPED WITH SPK1 07 UNVLr1 FIRMWARE WITH OPTIONAL ADA FEATURE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park...

Page 2: ...r assistance MODEL NUMBER MODEL SSP 571 D ADA EQUIPPED WITH SPK1 07UNVLr1 FIRMWARE SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have this information available...

Page 3: ...TION 4 2 0 GENERAL 4 3 0 PROGRAMMING 5 PROGRAMMING CONTINUED 7 4 0 TESTING OPERATION 8 5 0 RECOMMENDED TOOLS AND TEST EQUIPMENT 8 6 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 8 7 0 SPECIFICATIONS...

Page 4: ...e telephone is a sturdy vandal resistant Stainless Steel Panel Speakerphone Instead of a hookswitch and handset the SSP 571 D has a Press to start Press to stop CALL button for the initiation and term...

Page 5: ...the last page of this manual 3 4 Press the CALL button and wait for dial tone before programming any digits 3 5 It is important to be slow and deliberate when pressing the keys of the programming key...

Page 6: ...el Digit 6 0 No ADA Feature 9 Activate ADA Feature 9 must be entered to activate the ADA LED light Digit 7 0 Always 0 for this model Digit 8 PBX Access see section 3 9 0 Do not dial PBX access number...

Page 7: ...5 5 1 2 1 2 This will program the phone to automatically dial the number 555 1212 whenever the CALL button is pressed 3 9 If it is necessary for the telephone to automatically dial a PBX access code...

Page 8: ...e section 3 7 Digit 6 Otherwise the LED will remain RED during off hook periods A normal speakerphone conversation should be allowed 4 5 When the call is complete press the CALL button again to hang u...

Page 9: ...ection 6 5 The use of a gas tube or carbon station protector is recommended The station ground should not exceed 50 ohms 6 6 Plug the modular line cord from the SPK 660 000 PC board into the RJ11C ter...

Page 10: ...NE POWERED LOOP CURRENT 30a MIN 80ma MAX IMPEDANCE 600 Ohms SIGNALING DTMF 70ms tone 50ms spacing OUTPUT 4 0 to 6 0dbm ENVIRONMENTAL Temperature 0oC to 50oC Humidity 20 90 non condensating PROGRAMMING...

Page 11: ...OVER SECURITY SCREW 1 301 018 MODULAR LINE CORD 1 379 300 FACE PLATE 1 301 054 MODULAR CONNECTOR RJ11C 1 379 200 SERVICE MANUAL 1 700 008 KEYPAD CABLE 1 660 000 CEECO SPK BOARD 1 705 110 CONNECTORIZED...

Page 12: ...one Network through a registered jack provided by the Telephone Company in your area This jack is a modular outlet which you can order from your local telephone company 9 3 NOTIFICATION TO THE TELEPHO...

Page 13: ...ENT 863 357 0798 telephone 863 357 0006 facsimile info ceeco net www ceeco net 10 3 NON WARRANTY REPAIR CEECO will repair equipment out of warranty for a set charge plus parts The customer must pay th...

Page 14: ...t found to be defective by CEECO Under no circumstances shall CEECO be liable for loss damage cost of repair or consequential damages of any kind which have been caused by neglect abuse or improper op...

Page 15: ...hen programming is completed move the mini jumpers to the OFF position NOTE Do not leave the mini jumpers in the ON position this will decrease battery life Move the mini jumpers to the ON position BE...

Reviews: