PROGRAMMING CONTINUED…
EXAMPLE:
DIAL #00 0152090015
Phone will be set as follows:
DIGIT 1 .. CALL RESTRICTIONS IN EFFECT
DIGIT 2 .. INCOMING CALLS ALLOWED
DIGIT 3 .. 5 MINUTE TIME OUT FOR EMERGENCY CALLS
DIGIT 4 .. 2 MINUTE TIME OUT FOR BLACK CALL BUTTON
DIGIT 5 .. ALWAYS 0
DIGIT 6 .. ACTIVATE ADA LED
DIGIT 7 .. ALWAYS 0
DIGIT 8 .. DO NOT DIAL PBX NUMBER STORED IN LOCATION
#18
DIGIT 9 .. DIAL THE PBX ACCESS NUMBER FIRST FROM
LOCATION #02 (
SHORT PAUSE THEN DIAL EMERGENCY
NUMBER).
DIGIT 10 . 250MS WINK
LOCATION #01:
(
EMERGENCY NUMBER – RED BUTTON
)
#01 ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___
This location holds the
Emergency number
to be dialed.
Enter #01
followed by
the desired emergency number
. The number can be in the range of 1 to 11
digits. Whenever a caller pushes the "EMER" (RED) button the number in
location #01 will be dialed. If caller wants to hang up then he or she must push
the "CALL " button. The automatic time out disconnect features will begin to
work after the number has been dialed. The call will also disconnect when the
called end hangs up, provided the PBX gives the proper wink back on the line.
Be sure to record your number above for future reference.
LOCATION #02:
(
PBX - EMERGENCY NUMBER RED BUTTON
)
#02 ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___
This location holds any
PBX
number to be dialed
for
“Emergency”
Calls. If
this is desired,
enter #02, followed by the desired PBX number
. The number
can be from 1 to 11 digits. Any number stored in location #02 will automatically