CEECO SSP 361-D Service Manual Download Page 1

Issue 4.0 

 

MODEL SSP 361-D 

 

 

 STAINLESS STEEL PANEL 

TELEPHONE 

 

Equipped with ATD11 Board 

 
 
 
 

SERVICE MANUAL 

 
 

 
 
 
 
 
 
 
 
 

R

 

 

IMPORTANT INFORMATION 

COMMUNICATION EQUIPMENT AND ENGINEERING COMPANY

519 W South Park Street Okeechobee, FL  34972 
863-357-0798  telephone 
Serving The Telephone Industry Since 1930.

Summary of Contents for SSP 361-D

Page 1: ...L PANEL TELEPHONE Equipped with ATD11 Board SERVICE MANUAL R IMPORTANT INFORMATION COMMUNICATION EQUIPMENT AND ENGINEERING COMPANY 519 W South Park Street Okeechobee FL 34972 863 357 0798 telephone Se...

Page 2: ...ssistance MODEL NUMBER MODEL SSP 361 D EQUIPPED WITH ATD11 BOARD SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have this information available when calling for t...

Page 3: ...1 0 GENERAL DESCRIPTION 5 2 0 PROGRAMMING 5 3 0 OPERATION 6 4 0 RECOMMENDED TOOLS AND TEST EQUIPMENT 6 5 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 6 6 0 TESTING 7 7 0 TROUBLESHOOTING 8 8 0 SPECIF...

Page 4: ...enance information for Model SSP 361 D Stainless Steel Panel Telephone The information in this manual is subject to change without notification For information not included in this manual please call...

Page 5: ...position you will see just below the right hand corner of the A K main matrix board which contains ten green mini jumpers 2 2 If a 3 digit area code is to be dialed position the J3 green mini jumper o...

Page 6: ...flat vertical surface Mounting holes are provided on all sides and the back of the box 5 5 Run the inside station wire through the mounting box and terminate the Tip and Ring wires to the green and r...

Page 7: ...he position of J2 per Section 2 05 The programmed number is automatically dialed 6 3 The transmitter is muted while the phone is dialing 6 4 Incoming calls are not recommended but if a call is placed...

Page 8: ...NE POSSIBLE CAUSE LINE CORD CONNECTOR RJ11C CONNECTOR NETWORK HANDSET ATD 11A BOARD PROBLEM DIAL TONE IS DISTORTED POSSIBLE CAUSE NETWORK HANDSET PROBLEM TRANSMITTER DOES NOT TURN ON POSSIBLE CAUSE HA...

Page 9: ...T 23ma min to 80ma max IMPEDANCE 600 ohms HEARING AID COMPATIBLE Meets EIA standards ENVIRONMENTAL Temperature 0 C to 50 C Humidity 20 90 FACEPLATE Brushed 14 gauge Stainless Steel MOUNTING Apparatus...

Page 10: ...TD 11A Automatic Tone Dial 1 301 004 Handset with Armored Cord 1 401 009 Ringer 1 301 009 Network 1 301 588 Hookswitch Cradle 1 301 581 Tongue and Bracket Assembly 2 301 570 Microswitch Assembly 1 301...

Page 11: ...ephone Network through a registered jack provided by the telephone company in your area This jack is a modular outlet which you can order from your local telephone company 10 3 NOTIFICATION TO THE TEL...

Page 12: ...defective unit This information must be inside the shipping container 11 2 DIRECT ALL INQUIRES TO CEECO Repair Department 863 357 0798 telephone 863 357 0006 facsimile info ceeco net www ceeco net 11...

Page 13: ...und to be defective by CEECO Under no circumstances shall CEECO be liable for loss damage cost of repair or consequential damages of any kind which have been caused by neglect abuse act of God or impr...