CEECO HOB-331-D-M Service Manual Download Page 5

Issue 4.0 

CEECO 

Communication Equipment & Engineering Company 

PROPRIETARY 

5

  

 

3.0 PROGRAMMING 

 

NOTE: 

It is recommended that you ground yourself to prevent ESD 
damage to the PCB(s).  This can be done through the use of an 
electrostatic bracelet or other such device.  In the absence of any 
such device, it might suffice to simply touch a conduit or other 
grounded pipe or object to dissipate any built up static electricity.  

 

3.1 

Please refer to the diagram on the next page for mini-jumper location 

 

 and 

positioning.

  Programming is accomplished by position plastic 

 

hardware mini-jumpers in the proper positions for the desired calling 

 

pattern.  The mini-jumpers are designed to bridge pairs of copper pins to 

 

activate the desired dialing pattern.  

 

3.2

 

 

Locate the ATD-11 Automatic Dialer. 

  

3.3

 

 

If the number to be programmed is a (1+) call, position the J1 mini-jumper 

 

on the "1+" position, bridging the left and center copper pins. This will 

 

cause the digit "1" to be dialed in front of the other programmed digits.  If 

 

the number to be programmed is a local call, position the J1 mini-jumper 

 

on the "B" position, bridging the center and right copper pins.  

 

3.4

  

If a 3 digit area code is to be dialed, the J3 mini-jumper 

must

 be set to the 

"11" position, bridging the center and left copper pins.  If the number 
being dialed does not require the area code, position the J3 mini-jumper on 
the "8" position, bridging the center and right copper pins.  

 

3.5

 

Set each mini-jumpers on the A-K matrix board to correspond to the digits 
of the number to be dialed.  Beginning with column “A” at the top, 
position the plastic mini-jumper to bridge the pair of copper pins 
correspond to the desired digit (1-0).  Proceed in the same manner, from 
left to right, until all desired digits are programmed.  Do not skip any 
columns, as the digits must be represented in an unbroken string.  Any 
unused mini-jumpers 

must 

be removed from the board to ensure proper 

dialing.  Do not discard the unused jumpers, as they may be needed for 
future use.  It is recommended that they be taped or otherwise secured 
somewhere nearby, within the device.  Be sure each mini-jumper is 
properly positioned to make good contact and dial the intended number. 

 
 
 
 
 

 

Summary of Contents for HOB-331-D-M

Page 1: ...RESISTANT TELEPHONE and MODEL SSP 311 D M STAINLESS STEEL PANEL TELEPHONE EQUIPPED WITH ATD 11 AUTOMATIC DIALER AND RECEIVER OPERATED SEALED MAGNETIC HOOKSWITCH Serving the Telephone Industry Since 19...

Page 2: ...llowing information is necessary when calling CEECO for assistance MODEL NUMBER SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED Please keep this information on hand when calling CEECO for technical...

Page 3: ...NERAL DESCRIPTION 4 3 0 PROGRAMMING 5 4 0 OPERATION 6 5 0 RECOMMENDED TOOLS AND TEST EQUIPMENT 6 PROGRAMMING DIAGRAM 7 6 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 8 7 0 TESTING 10 8 0 TROUBLESHOO...

Page 4: ...D 11 automatic tone dialer that will dial a single number of up to eleven 11 digits The auto dialing feature is activated by hook switch closure The CEECO Model HOB 331 D M is a Weather Resistant Tele...

Page 5: ...digits If the number to be programmed is a local call position the J1 mini jumper on the B position bridging the center and right copper pins 3 4 If a 3 digit area code is to be dialed the J3 mini ju...

Page 6: ...found approximately 1 5 1 75 directly below the J1 and J3 positions and is somewhat by itself Position the J2 plastic mini jumper so that it bridges the middle and far right copper pins A 3 appears in...

Page 7: ...Issue 4 0 CEECO Communication Equipment Engineering Company PROPRIETARY 7 PROGRAMMING DIAGRAM...

Page 8: ...desired Mounting hardware is not included The housings are designed to be mounted on a flat vertical surface Mounting holes are provided on the back of the housings In the case of the HOB model a suit...

Page 9: ...FIDENTIAL This drawing and all information contained therein is confidential and is the exclusive property of CEECO and may not be copied reproduced or disclosed to anyone in any manner whatsoever or...

Page 10: ...a call is placed to the phone and the handset is lifted there is a one and one half to four second delay depending on the position of J2 Section 3 6 the programmed number is dialed and then a normal...

Page 11: ...any PROPRIETARY 11 TROUBLESHOOTING CONTINUED PROBLEM PHONE DOESN T DIAL PROGRAMMED NUMBER POSSIBLE CAUSE ATD 11 PRINTED CIRCUIT BOARD PROGRAMMING SWITCH MATRIX SET WRONG JUMPER IN WRONG POSITION PROBL...

Page 12: ...Steel ENCLOSURE WPP Model Cast Aluminum HOB Model Painted Steel DIMENSIONS WPP Model 12 5 8 High x 9 1 2 Wide x 8 Deep including door HOB Model 11 1 4 High x 7 1 16 Wide x 5 Deep SSP Model 11 1 4 Hig...

Page 13: ...D 11 Automatic tone dial 1 401 009 Ringer 1 301 009 Network 1 301 592 Magnetic Hook switch 1 301 018 Modular cord 1 331 003 Stainless steel panel for D and X models 1 301 054 Modular jack 4 331 006 Se...

Page 14: ...hone Network through a registered jack provided by the telephone company in your area This jack is a modular outlet which you can order from your local telephone company 11 3 NOTIFICATION TO THE TELEP...

Page 15: ...he defective unit This information must be inside the shipping container 12 2 DIRECT ALL INQUIRES TO CEECO Repair Department 519 West South Park Street Okeechobee Florida 34972 863 357 0798 12 3 NON W...

Page 16: ...d to be defective by CEECO Under no circumstances shall CEECO be liable for loss damage cost of repair or consequential damages of any kind which have been caused by neglect abuse act of God or improp...

Reviews: