CEECO BLW-321-F-IVC-C-M Service Manual Download Page 5

Issue 4.00

 

CEECO

 

Communication Equipment and Engineering Company 

PROPRIETARY 

5

5.0  INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 

 

5.1 

Using a 301-037 security tool (sold separately) loosen and remove the 
security screw. 

 

5.2

 

The security tool is for a standard 5/32" button head screw generally used 
on the framework of the phone booths. 

 
 

5.3

 

Separate the cover assembly from the backplate assembly. 

 
 

5.4

 

The backplate assembly may be installed on any standard backboard. 

 

 

5.5

 

Run the inside station wire through the backplate assembly and terminate  
on the RJ11C modular jack on the backplate, as depicted on the following 
page. The CEECO-provided modular jack 

must

 be used, as it contains 

required over-voltage protection.  

 

5.6

 

The use of a gas tube station protector is recommended.  The station 
ground should not exceed 50 ohms.  

 

5.7

 

Plug the modular line cord from the cover assembly into the RJ11C 
terminal block. 

 

5.8

 

Dress the line cable away from the security screw and install the cover 
assembly by inserting the tabs into the slots on top of the backplate.   

 
 

5.9

 

Secure the cover assembly by tightening the security screw.

 

 
 
 
 

 

*****WARNING*****

 

 
 
 

A.  

Never install telephone wiring during a lightning storm. 

 

B.  

Never install telephone jacks in wet locations unless the jack is 
specifically designed for wet locations. 

 

C.  

Never touch uninsulated telephone wires or terminals unless the 
telephone line has been disconnected at the network interface. 

 
 

D.  

Use caution when installing or modifying telephone lines. 

 

 

 
 

Summary of Contents for BLW-321-F-IVC-C-M

Page 1: ...CE MANUAL FOR MODEL SSW 321 F IVC C M OR MODEL BLW 321 F IVC C M MINI WALL TELEPHONE Serving the Telephone Industry Since 1930 Communication Equipment 519 West South Park Street Engineering Company Ok...

Page 2: ...ing CEECO for assistance MODEL NUMBER SSW 321 F IVC C M OR BLW 321 F IVC C M SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have this information available when c...

Page 3: ...ECTION PAGE 1 0 INTRODUCTION 4 2 0 GENERAL DESCRIPTION 4 3 0 OPERATION 4 4 0 RECOMMENDED TOOLS AND TEST EQUIPMENT 4 5 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 5 6 0 TESTING 6 7 0 SPECIFICATIONS...

Page 4: ...1 F IVC C M or BLW 321 F IVC C M is a Mini Wall Telephone equipped with a metal button tone dial The telephone is designed for special applications where a telephone must be both sturdy and attractive...

Page 5: ...modular jack must be used as it contains required over voltage protection 5 6 The use of a gas tube station protector is recommended The station ground should not exceed 50 ohms 5 7 Plug the modular l...

Page 6: ...0 TESTING 6 1 Connect the phone to a phone line or a DTMF phone test set 6 2 Lift the handset dial tone is heard 6 3 Dial a number The transmitter is muted while the phone is dialing 6 4 Normal phone...

Page 7: ...ms SIGNALING DTMF HEARING AID COMPATIBLE Meets EIA standards ENVIRONMENTAL Temperature 0 C to 50 C Humidity 20 90 non condensating RINGER EQUIVALENCY 0 4A TYPE JACK RJ11C TELEPHONE COVER Brushed 16 ga...

Page 8: ...0 Metal Button Tone Dial 1 301 004 32 Handset with Armored Cord 1 401 009 Ringer 1 301 009 Network 1 301 592 Magnetic Hookswitch Assembly 1 301 018 Modular Cord 1 321 015 Stainless Steel Backplate 1 3...

Page 9: ...etwork through a registered jack provided by the telephone company in your area This jack is a modular outlet which you can order from your local telephone company 9 3 NOTIFICATION TO THE TELEPHONE CO...

Page 10: ...n must be inside the shipping container 10 2 DIRECT ALL INQUIRES TO CEECO Repair Department 863 357 0798 telephone 863 357 0006 facsimile info ceeco net www ceeco net 10 3 NON WARRANTY REPAIR CEECO wi...

Page 11: ...of any kind which have been caused by neglect abuse or improper operation of equipment CEECO will repair or replace any unit during this period if found to be defective for reasons other than abuse an...

Reviews: