TOF/Start
English
© CEDES | V 1.1
5
Important:
The scale is not printed on the sensor. However the
potentiometer can be adjusted in five fixed steps of 0.2
m; starting at 0.6 m (at the 7 o'clock position) up to
1.4 m (at the 5 o'clock position); see Figure 3 below.
Take a small screw driver and turn the potentiometer
to the required position.
(all dimensions in mm)
Figure 3:
Detection area using potentiometer
Table 1:
Parameter - detection area
6. Installation
Important:
The TOF/Start must be mounted under the handrail at a
minimum 10° mounting angle
to the ground facing
upwards.
Figure 4:
Mounting angle of TOF/Start
7. Input / Output description and
electrical connection
Generally the TOF/Start has one output that is triggered
if the detection field is interrupted. For this purpose, a
push-pull output is used. With the logic selector (gray wire,
Figure 6), the logic of the output signal can be configured
for “HIGH“ on object or “LOW“ on object operation
(Figure 5), according to the controller requirements.
The logic selection is performed during start-up.
Figure 5:
Output (PNP/NPN) logic
Figure 6:
Connection diagram
8. Start-up
1. Switch on mains and power up.
2. Check if LED lights up.
3. Check the distance setting and the reaction of the
sensor, including the status LED, by placing an object
into the detection area at different heights and widths.
70°
20°
1.4 m
1.0 m
0.6 m
0.8 m
1.2 m
x-axis
x = min. 600 ... max. 1400
y = 2000
Parameter
Value
Width (x-axis)
Min.: 600 mm
Max.: 1,400 mm
Length (y-axis)
2,000 mm
Aperture angle
70°
U
SP
0 V
Output
Logic selector connected to GND (0 V)
U
SP
0 V
Output
Logic selector connected to U
SP
Con
tr
oller
U
SP
GND (0 V)
n.c.
Selectable output logic
Output
n.c. = not connected and isolated
n.c.
black
brown
green
blue
white
gray
TOF/Start
10°