READY WARM 800/1200/1800/2000/2500 THERMAL CONNECTED
READY WARM 800/1200/1800/2000/2500 THERMAL CONNECTED
31
30
ENGLISH
ENGLISH
The device must never be installed in a position where the switches and other controls can
be reached by someone in the bath or shower.
The heater works through natural air convection. In order to achieve correct performance
and uniform heat distribution, when it is installed on a wall, the lower part of the heater must
be at a minimum distance of 20 cm from the floor, a minimum distance of 20 cm from the
sides, 50 cm from an upper shelf and a minimum distance of 20 cm from any wall or object
(furniture and curtains etc.).
Fig. 3.
Fig. 4.
Wall installation
Select a suitable location on the wall, which should be firm and level. Check that there is a
mains socket close by.
The distances marked, “a” and “e” vary depending on the heater model.
Fig. 5.
Reference distances by model:
Models
A (mm) B (mm) E (mm)
F (mm)
Ready Warm 800 Thermal Connected / 05372
410
93
140
495
Ready Warm 1200 Thermal Connected / 05373
550
93
280
495
Ready Warm 1800 Thermal Connected / 05374
690
93
420
495
Ready Warm 2000 Thermal Connected / 05375 830
93
560
495
Ready Warm 2500 Thermal Connected / 05376
970
93
700
495
Fig. 6.
Respecting the previously indicated safety measurements, make two marks on the wall
according to measurement “e” indicated in Table 1 and at a height of 695 mm from the floor.
At the marked area drill 2 10-mm diameter holes, with a minimum depth of 60 mm.
Push the two plugs (D) into the two holes and secure the two hooks (C) with the two screws
(D).
Screw the two support brackets (A) (or one support bracket, depending on the model) to the
rear part of the heater with the four screws (E) (or two screws, depending on the model).
The two brackets (A) are screwed to the holes located on the lower rear part of the heater, at
both ends.
Fig. 7.
Hang the heater on the two hooks (C) on the wall. Ensure that the heater is correctly secured
on both hooks.
Fig. 8.
When the heater is hung in place, make two marks on the wall where the two brackets (A) will
be fixed to ensure the heater is fixed to the wall.
Fig. 9.
Remove the heater and drill two 4-mm diameter holes, with a minimum depth of 25 mm at
the
two marks on the wall.
Insert the two plugs and secure with the two screws (B) to completely secure the heater to
the wall.
Fig. 10.
Floor installation
Installing the feet
Screw the two feet to the lower rear part of the heater with the four screws provided (F), 2
screws per foot.
Fig. 11.
4. OPERATION
Place the device on a flat, stable surface.
Plug it and turn it on from the side switch. The device will beep.
Press the on/off button. The LED display will show the room temperature.
Use the control panel or remote control to set the desired power, temperature and operating
time.
The device will beep every time a button is pressed.
Touch control panel
Fig. 12.
1. Display
2. On/Off button
3. Wi-Fi signal
4. Temperature
5. Timer
6. Mode
Turning the device on and off
Press the on/off button on the display to turn the device on and off. When turned on, the
device will operate at low power by default and the display will show temperature.