16
CE10 OPERATIONS MANUAL & PARTS LIST
(Rev. 6/2021)
4.2
– DISCHARGING FLUID FROM THE SUMP CLEANER DIRTY TANK
1. ATTACH THE SUMP CLEANER HOSE TO THE DIRTY TANK DISCHARGE
PORT, AND CAP THE SUCTION PORT.
2. RUN UNIT ON DISCHARGE MODE. (SEE INITIAL STARTUP 3.5, STEP 6.)
3. POINT NOZZLE AT THE TARGET WHERE THE FLUID IS TO BE DISPENSED,
SLOWLY OPEN DIRTY TANK DISCHARGE VALVE. SLUGS OF AIR WILL
PASS THROUGH HOSE WHEN TANK APPROACHES EMPTY. THESE SLUGS
CAN CAUSE ERRATIC FLUID FLOWS, BE PREPARED TO SHUT OF
DISCHARGE VALVE WHEN THIS OCCURS.