background image

5

Gently push
bowl back and
up to unlock
the latch as
shown in the
picture.

Must be
unhooked 
to remove
bowl.

Pull bowl
forward
to remove
from unit.

To Remove Bowl

2

1

To Replace Bowl

A

C

B

To properly fasten bowl, reverse
each step by doing the following:

1. Start with Step C, push forward  

and firmly press down.

2. In Step B, make sure bowl is 

hooked properly.

3. Final Step A, double check if  

bowl is securely locked under 
lip of the machine.

Summary of Contents for MT-2-UL

Page 1: ...enue Long Island City NY 11105 Tel 718 932 1414 Fax 718 932 7860 Visit us on the web www cecilware com E mail customer service cecilware com FrigoGranita Frozen Beverage Dispenser Maintenance Manual N...

Page 2: ...ink Mode when a machine is in drink mode the beverage temperature is controlled by the corresponding thermostat O Off Slush Mode when a machine is in slush mode the mix viscosity is controlled by the...

Page 3: ...light to be on top cover metal tab must touch the verticle wire To replace bulb and remove graphics remove screw from cover Verticle wire must touch flexible light contact on upper drip tray LightedTo...

Page 4: ...agnetic Auger Gently turn scraping blade clockwise to disengage it from the auger With one hand supporting the freezing chamber pull the auger out note magnetic pull will be strong until the attractio...

Page 5: ...forward to remove from unit To Remove Bowl 2 1 To Replace Bowl A C B To properly fasten bowl reverse each step by doing the following 1 Start with Step C push forward and firmly press down 2 In Step...

Page 6: ...6 1 Pull pin out 2 Remove handle spring 3 Push faucet piston up from below and out of the bowl Pin Spring Handle Faucet Piston To Remove Handle Assembly...

Page 7: ...7 Faucet Piston Lubricate both O Rings with Food Grade Lubricant Magnetic Auger Lubricate auger bushing Lubricate nose of outer spiral When Assembling Unit The Following Must Be Lubricated...

Page 8: ...ket by gently pulling gasket forward around the freezing chamber Replace gasket by gently pushing forward until gasket fits properly around gasket seat Do not use any lubricant on gasket To Remove Rep...

Page 9: ...minute intervals Thickness Control Setting To change the viscosity if necessary use a standard screwdriver to turn the adjustment screw located in the rear wall of each container as follow Clockwise r...

Page 10: ...10...

Page 11: ...30 00092 4 leg 1 27 00 31 00120 Solenoid valve coil 41 00 33 00087 Density adjustment screw 5 50 34 00089 Shaped nut 3 70 35 00088 Density spring 2 30 36 00121 Microswitch 9 50 37 00227 Rear wall rea...

Page 12: ...el by turning both thumb screws counter clockwise and pull off stainless steel shield Washable Filter Condenser If placed next to another machine or object allow 6 of space to provide ample air intake...