background image

AUTOMATIC  

HOT WATER BOILER

 

ELECTRICAL SPECIFICATIONS

 

 

MODEL No.

 

VOLTS

 

WATTS

 

AMPS

 

PHASE

 

FIELD 

WIRING SIZE

 

120

 

1,800

 

15.0

 

1

 

14AWG

 

 

ME-10E

 

240

 

7,000

 

29.2

 

1

 

10AWG

 

208

 

5,300

 

25.5

 

1

 

10AWG

 

ME-15E 

 

ME-30E

 

240

 

10,500

 

25.0

 

3

 

10AWG

 

 
 

208

 

7,900

 

22.0

 

3

 

10AWG

 

 

NOTE: FIELD WIRING MUST BE SUITABLE FOR 75 DEGREES CELCIUS.  

USE COPPER WIRE ONLY FOR POWER SUPPLY CONNECTION.

 

COPPER WIRE: 14 AWG MINIMUM COPPER ONLY.

 

WARRANTY 

Every Cecilware product has been carefully inspected before shipment. The finest of materials and the highest 
standards of workmanship have been but into the equipment. 
Within 1 year of purchase, should any Cecilware product show defect in factory workmanship or material, we agree to 
Repair, at our option or replace without cost to user such parts which prove upon factory inspection to have been so 
defective. All equipment must be shipped transportation charges  prepaid for acceptance.  This warranty covers 
replacement parts only, labor charges are covered for 90 days after installation. 
This warranty does not apply under the following conditions: 

• neglect or abuse of equipment 
• excessive lime condition 
• Improper installation 
• any outside modification to equipment 

Every Cecilware urn body is covered for three years. This warranty covers the stainless steel body and stainless steel 
liners only. 
Portable equipment such as Electric Fryers, Food Warmers, Electric Stoves, Dispensers, Plug-In Urns, Coffee 
Brewers and Warmers must be returned to the factory or brought to an authorized service station for repair. 

 

UNPACKING INSTRUCTION:

 Carefully unpack the water boiler and inspect immediately for 

shipping damages. Your automatic water boiler was shipped in a carton designed to give maximum 
protection in normal handling. It was thoroughly inspected before leaving the factory and the carrier 
accepted and signed for it. File any claims for shipping damage or irregularities directly with the 
carrier.

 

CECILWARE CORPORATION 

      

43-05 20th AVENUE, LONG ISLAND CITY, N.Y. 11105 • 718-932-1414 • FAX 718-932-7860 

N796A-10/98 

 

OPERATION MANUAL 

Contents 

Specifications 

Installation 

Maintenance Tips 

Repair Parts List 

Wiring Diagrams

 

MODEL No. 

ME-10E 
ME-15E 
ME-30E

 

Summary of Contents for ME-10E

Page 1: ...ter installation This warranty does not apply under the following conditions neglect or abuse of equipment excessive lime condition Improper installation any outside modification to equipment Every Ce...

Page 2: ...o leave at lest 6 on the right side of the water boiler for access to the controls Level the unit by adjusting the bottom pad of the legs Screw the ball float 36 onto the end of the water inlet valve...

Page 3: ...t be performed by a qualified serviceman 1 and 3 phase hook up Remove the fasteners on the cover and slide off cover Install a suitable conduit and connect copper wires to terminal L1 and L2 and L3 fo...

Page 4: ...lary tube 7 Install new thermostat Position capillary end of thermostat bulb two 2 inches from inside wall 8 Tighten large packing nut then small capillary nut DO NOT over tighten since this could dam...

Page 5: ...n Still no reading replace Hi Limit switch Water fails to heat Thermostat Pilot light should be on when thermostat is in the full on position 5 position If not replace thermostat and recalibrate see c...

Page 6: ...phase VOLTS 208 240 50 60 HZ WATTS 7900 10500 AMPS 22 25 PHASE 3 ME10E 15E 120V 208 240 V 1 phase VOLTS 208 240 50 60 HZ WATTS 5300 7000 AMPS 25 5 29 2 PHASE 1 120 Volt Hook Up VOLTS 120 50 60 HZ WAT...

Page 7: ...J11 1 ME 10 15 E WATER BOILER PARTS ILLUSTRATION 7...

Page 8: ...ermometer L007A L007A 34 Stem Valve M0251 M0251 15 Chrome Plated Nut NPT K110A K110A 35 Adapter 20 M0589 M0589 16 Body R479A R480A 36 S S Float 3 M0892 M0892 17 Legs set of 4 M005S M005S 37 Knob M027A...

Reviews: