START-UP PROCEDURE
Caution: Make sure that the Heater Switches, are in the OFF position.
1. Connect the
¼
inch
copper waterlines to the
¼
inch flare water inlet fittings of the valves.
2. Plug the power cords into dedicated receptacles.
3. Activate the
Power Switch
(Toggle Up). The door display panel, the red power indicator lights
and the green dispense buttons will light up and the
tanks will start filling. Allow approximately
4-5 minutes for the tanks to fill.
4. Activate the
Heater Switch
. Allow approximately 10-30 minutes for the water to reach the
proper dispensing temperature of 190° F. The heat up time will depend on the water inlet
temperature, the input voltage and the wattage of the elements in the water tanks.
5. Place a
cup under the dispense nozzle, press and hold the dispense switch for 6 seconds. The unit
will dispense water at the rate of 1 oz. per second. Repeat it several times to check for consistent
output. Repeat same for the other dispense switches. This procedure checks that the dispense
valves are not “air-locked.”
6. While the water tanks are heating up, the
heater light
comes on. Remove the hoppers, load them
with product and reposition them back in place. When the
heater light
turns off, the water tanks
have reached their proper temperature and are ready to dispense the first cup of Cappuccino
.
TO DIPENSE A CUP OF CAPPUCCINO:
Place a cup under the selected drink dispense nozzle.
Push and hold dispense button until cup is 2/3 full, then release button.
Summary of Contents for GB4M-5.5-LD-U
Page 1: ...Operation Manual NL48A July 2005 GB4M 5 5 LD U GB5 LD U GB6M 10 LD U GB8M 10 LD U...
Page 16: ...DESCRIPTION ITEM QTY P N...
Page 17: ...DESCRIPTION ITEM QTY P N...
Page 18: ...DESCRIPTION ITEM QTY P N...
Page 19: ...DESCRIPTION ITEM QTY P N...
Page 20: ...DESCRIPTION ITEM GB8 GB6 GB5 UPPER DOOR GB4M 5 5 LD U GB5 LD U GB6M 10 LD U GB8M 10 LD U GB4...
Page 21: ...DESCRIPTION ITEM GB6 GB8 GB5 GB4 LOWER DOOR GB4M 5 5 LD U GB5 LD U GB6M 10 LD U GB8M 10 LD U...
Page 22: ...DESCRIPTION ITEM QTY P N...
Page 23: ...DESCRIPTION ITEM QTY P N TANK DIMENSIONS 12 WIDE 4 8 DEEP 16 5 HIGH APPROX 3 7 GAL...
Page 24: ...DESCRIPTION ITEM QTY P N TANK DIMENSIONS 15 WIDE 6 DEEP 18 HIGH APPROX 6 GAL...
Page 25: ......
Page 27: ...GB6M 10 LD U...