background image

2

Cecilware

®

Electric Cheesemelter

Important Safety Information

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages
that follow this symbol to avoid possible injury or death.

WARNING

• Do not deform power cord.
• Follow national and local electrical codes.
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
• Use only on a dedicated circuit load that is properly protected and capable of the rated load. Do not use
extension cords, as this could result in electrical shock, overheating, and fire.
• Risk of electrical shock. Disconnect power before servicing or cleaning unit. Contact Grindmaster-Cecilware
Technical Service for service assistance.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agents or similarly
qualified persons in order to avoid a hazard.
FAILURE TO COMPLY TO THE ABOVE RISKS PERSONAL INJURY, SHOCK HAZARD, FIRE, OR DAMAGE TO
EQUIPMENT.

CAUTION

• Read and understand the operating instructions in this manual thoroughly. Only allow properly trained
persons to operate this machine.

• Stay alert at all times during operation.

• Operate with care. Surfaces will get very hot and may cause serious burns.

• Keep operating area clean.

For your safety and the safety of others, read all warnings and the operator’s manual before installing or using
the product. 

DANGER:

This term warns the user of imminent hazard that will result in serious injury or death.

WARNING:

This term refers to a potential hazard or unsafe practice, which could result in serious injury or

death.

CAUTION:

This term refers to a potential hazard or unsafe practice, which could result in minor or moderate

injury.

NOTICE:

This term refers to information that needs special attention or must be fully understood.

Unpacking

Carefully lift unit out of shipping container, and inspect
immediately for shipping damage. Your Cheesemelter
was shipped in a carton designed to give it maximum
protection. It was thoroughly inspected before leaving
the factory. File any claims for shipping damage or
irregularities directly with the carrier.

Installation

Mechanical Installation
Counter location: 

Select a suitable location for your

cheesemelter and adjust the leveling legs on the
bottom of the unit to level it and prevent rocking.
Height may be adjusted by turning the feet up or down
as desired.

Pass-thru location:

Remove the outer and inner back

panels and adjust the leveling legs. 

Wall mounted:

Remove the outer back panel and

mount the wall brackets to the back of the unit using
the same screws. Refer to diagram on page 4. Position
the Cheesemelter on the wall and mark the four holes
through the mounting brackets on the wall. Use 5/16”
diameter toggle bolts 2" long or an equivalent fastener
to mount the unit to the wall.

Safety Information

NOTICE

Summary of Contents for CM24M

Page 1: ...nd List 4 Wiring Diagram 4 Thank you for purchasing this quality Cheesemelter For your safety and the safety of others read all warnings and the operator s manual before installing or using the product Properly instruct all operators Keep training records For future reference record serial number here Table of Contents 2016 Grindmaster Cecilware Printed in USA 0516 Form CW 341 01 Part 390 00088 Gr...

Page 2: ... read all warnings and the operator s manual before installing or using the product DANGER This term warns the user of imminent hazard that will result in serious injury or death WARNING This term refers to a potential hazard or unsafe practice which could result in serious injury or death CAUTION This term refers to a potential hazard or unsafe practice which could result in minor or moderate inj...

Page 3: ... element being careful that the wires do not fall behind the panel 4 Replace the element in the reverse order of removal B Quartz Tube Element 1 Remove quartz element bracket mounting screws from one side of the cheesemelter 2 Lower the bracket 9 to clear the quartz elements and withdraw the guard rods 10 from the other bracket 3 Remove the other bracket 4 Slide the element 1 A to one side to clea...

Page 4: ...t 8 Description CM24M CM24Q CM36M CM36Q 1 208V 240V 1500W Heating Element G101A 120V 1500W Heating Element 320 00064 1A 208V 240V 900W Quartz Element G191A 120V 500W Quartz Element 320 00065 2 Infinite Switch 344 00035 344 00035 L040A L040A 3 Infinite Switch Knob M060A M060A M060A M060A 4 Pilot Light C164A C164A C164A C164A 5 Line Cord C032A C032A 6 Adjustable Legs 71256 71256 71256 71256 7 Wire R...