Cecilware BG 12 Operation Manual Download Page 5

 

PARTS LIST 

FIG # 

ITEM  

BG 12 

BG24 

BG36 

BG48 

Griddle Plate Ass'y 

S213Q 

S214Q 

S215Q 

S216Q 

Heat Shield 

T680A 

T665A 

T690A 

T700A 

Gas Burner Right Side 

G236A 

G236A 

G236A 

Gas Burner Left Side 

G237A 

G237A 

G237A 

G237A 

Gas Orifice Hood (N) 

F234A 

F234A 

F234A 

F234A 

 
 

Gas Orifice Hood (P)  

F235A 

F235A 

F235A 

F235A 

Gas Valve 

F196A 

F196A 

F196A 

F196A 

Gas Manifold Pipe 

F230A 

F231A 

F232A 

F233A 

Brass Plug 

K044A 

K044A 

K044A 

K044A 

Pilot Light Adj. Valve 

F019A 

F019A 

F019A 

F019A 

10 

Gas Valve Knob 

M241A 

M241A 

M241A 

M241A 

11 

Front Panel 

T683A 

T663A 

T689A 

T701A 

12 

Nut Retainer 

P297A 

P297A 

P297A 

P297A 

13 

Grease Drawer 

T704Q 

T704Q 

T704Q 

T704Q 

14 

Bottom Panel 

T708A 

T705A 

T706A 

T704A 

15 

Body Wrap 

T662A 

T668A 

T669A 

T694A 

16 

Pilot Burner Ass'y (N) 

F135A 

F135A 

F135A 

F135A 

 
 

Pilot Burner Ass'y (P)  

F134A 

F134A 

F134A 

F134A 

17 

Adjustable Leg (Set) 

M005S 

M005S 

M005S 

M005S 

18 

Rear Panel 

T670A 

T671A 

T672A 

T695S 

19 

Gas Press. Reg. (N) 

L053A 

L053A 

L053A 

L053A 

20 

Gas Press. Reg. (P)  

L203A 

L203A 

L203A 

L203A 

21 

Flue Back 

T715A 

T716A 

T717A 

T718A 

22 

Fascia 

U878A 

U869A 

U870A 

U871A 

 

Summary of Contents for BG 12

Page 1: ...wer with baffle 7 Supplied with adjustable NSF listed legs 8 A G A design certified 9 MEA Listed 10 NSF Listed FOR YOUR SAFETY DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance This installation must conform with local codes with the National Fuel Gas Code ANSI Z223 1 latest edition Natural Gas Installation Code CAN CGA B149 1 or the ...

Page 2: ...he National Gas Installation Code CAN CGS B149 1 or the Propane Installation Code CAN CGA B149 2 as applicable 6 Provide adequate air supply and ventilation 7 Provide adequate clearance for air openings into the combustion chamber 8 Provide clearances for servicing and operation This unit is for use only on non combustible floors Minimum clearances from combustible and non combustible construction...

Page 3: ...ion before attempting to light the griddle Inspect the burners to see that they are properly seated on the support bracket at the rear and properly located on the burner orifices The griddle is now ready for lighting LIGHTING INSTRUCTIONS These lighting instructions are to be followed for installation only For normal operation follow the simple instructions on the gas specification label attached ...

Page 4: ...keep your griddle clean and sparkling but will prevent grease accumulations from forming A well cleaned griddle will give you many years of service and perform more efficiently OUTSIDE SERVICE Should you require help contact the factory your factory representative or your local service company FOR QUALIFIED SERVICE PERSONS ONLY When servicing of unit is required contact a qualified service agency ...

Page 5: ... Pilot Light Adj Valve F019A F019A F019A F019A 10 Gas Valve Knob M241A M241A M241A M241A 11 Front Panel T683A T663A T689A T701A 12 Nut Retainer P297A P297A P297A P297A 13 Grease Drawer T704Q T704Q T704Q T704Q 14 Bottom Panel T708A T705A T706A T704A 15 Body Wrap T662A T668A T669A T694A 16 Pilot Burner Ass y N F135A F135A F135A F135A Pilot Burner Ass y P F134A F134A F134A F134A 17 Adjustable Leg Set...