15
0.1 to 10 seconds (default 0,5 sec.). The switching time
(
Slope Time
) between the starting current (
Start Curr
)
and the welding current may also be adjusted from 0.1
to 10 seconds (default 0.5 seconds.).
HSA
ON
Start Curr.
135%
0,5s
S.C. Time
Slope Time
0,5s
Process Params
Start Curr
10
200
135%
S.C Time
0.5s
0.1s
10.0s
Slope Time
0.5s
0.1s
10.0s
•
CRA (crater filler - final crater filling)
.
This function is blocked when function 3L is activated.
It is working during welding
2T
,
4T
and also in
combination with function
HSA
.
After activating the function, the operator may adjust
the connection time (
Slope Time
) between the welding
current and the crater filling current (
Crater Curr.
) from
0.1 to 10 seconds (default 0.5 seconds.).
The operator may also adjust the crater filling current
(
Crater Curr.
) from 10 to 200% of the welding current
(Default 60%).
The time (
C.C. Time
) of the crater filling duration may
also be adjusted from 0.1 to 10 seconds (default 0.5
seconds).
CRA
ON
Slope Time
0,5s
Crater Current
60%
C.C. Time
0,5s
Process Params
Slope Time
0.5s
0.1s
10.0s
Crater Curr
10
200
60%
C.C. Time
0.5s
0.1s
10.0s
•
Inductance
Adjustment can vary from -9.9 to +9.9. Factory setting
is zero. If the figure is negative, the impedance drops
and the arc becomes harder, while if it increases, the
arc is softer.
To access this function, simply highlight it using the
knob
B
and press it for less than 2 seconds. The display
screen
A
shows the adjustment bar. The figure can be
changed and confirmed by pressing the knob
B
for less
than 2 seconds.
Inductance
0.0
Burn Back
Auto
Soft Start
Auto
Pre Gas
0,1s
Process Params
Inductance
MIN
MAX
0.0
•
AUTO burnback
The adjustment can vary from -9.9 to +9.9. Its purpose
is to adjust the length of the wire coming out of the gas
nozzle after welding. A positive figure corresponds to
greater wire burning.
Default is Auto (preset function). To access this
function, simply highlight it using the knob
B
and
press it for less than 2 seconds. The display screen
A
shows the adjustment bar. The figure can be changed
and confirmed by pressing the knob
B
for less than 2
seconds.
Burn Back
Auto
Soft Start
Auto
Pre Gas
0,1s
Post Gas
3,0s
Process Params
Burnback
MIN
MAX
0.0
•
Soft Start AUTO
Adjustment can vary from 0 to 100%. This is the wire
speed expressed in percentage of the speed set
for welding, before the wire touches the piece to be
welded.
This adjustment is important to always obtain good
starts.
Default is Auto (preset function).
To access this function, simply highlight it using the
knob
B
and press it for less than 2 seconds. The display
screen
A
shows the adjustment bar. The figure can be
changed and confirmed by pressing the knob
B
for less
than 2 seconds.
Soft Start
AUTO
Gas
0,1s
Pre
Post Gas
3,0s
LCD Contrast
50%
Process Params
Soft Start
MIN
MAX
60%
• Pre Gas
PreGas
0.0s
10.0s
0.1s
The adjustment can vary from 0 to 10 seconds.
To access this function, simply highlight it using the
knob
B
and press it for less than 2 seconds. The display
screen
A
shows the adjustment bar. The figure can be
changed and confirmed by pressing the knob
B
for less
than 2 seconds.