background image

www.cebek.com

    -    [email protected]

I-302

TIMER TYPES 

  -  TYPES DE TEMPORISATEUR  -  TIPOS DE TEMPORIZADOR

FUNCTIONS

Cyclic / Voltage / ON/OFF

Cyclic / Voltage / OFF/ON

Cyclic / Push button / ON/OFF

Cyclic / Push button / OFF/ON

Timered  / With Delay  / ON/OFF

Timered  / With Delay  / OFF/ON

Reactivation – OFF Delalay / Push button

Reactivation – ON Delalay / Push button

1 - Cyclic through voltage ON/OFF (Equivalent to I-10, I-11 et I-12) 

Connecting the power supply, the relay will be activated during the ON time and it will be deactivated during the OFF time. At the end of the OFF time, 
the ON time start again. 

2 - 

Cyclic through voltage OFF/ON 

Connecting the power supply, the relay will be activated during the OFF time and it will be deactivated during the ON time. At the end of the ON time, 
the OFF time start again. 

3 - Cyclic through push button ON/OFF 

Closing the START button, the relay will be activated during the ON time. At the end of the ON time, the relay will be deactivated during the OFF time. 
At the end of the OFF time, the ON time start again. 

4 - Cyclic through push button OFF/ON 

Closing the START button, the relay will be activated during the OFF time. At the end of the OFF time, the relay will be deactivated during the ON 
time. At the end of the ON time, the OFF time start again. 

5 - Timing with Delay through voltage (Equivalent to I-33 and I-34) 

Connecting the power supply, the OFF timing will be activated without connecting the relay. At the end of the OFF time, the relay is connected during 
the ON time. 

6 - Timing with Delay through push button (Equivalent to I-33 and I-34) 

Closing the START button, the OFF timing will be activated without connecting the relay. At the end of the OFF time, the relay is connected during the 
ON time. 

7 – Timing with Delay and Reactivation OFF through push button 

Closing the START button, the OFF timing will be activated without connecting the relay. At the end of the OFF time, the relay is connected during the 
ON time. If during the ON timing the push button is closed, the timing is reset and the OFF time start again. It doesn’t affect the ON time. 

8 – Timing with Delay and Reactivation ON through push button 

Closing the START button, the OFF timing will be activated without connecting the relay. At the end of the OFF time, the relay is connected during the 
ON time. If during the ON timing the push button is closed, the timing is reset and the ON time start again. It doesn’t affect the OFF time. 

1 – Cyclique par tension ON / OFF (Équivalent I-10, I-11 et I-12)

En connectant l’alimentation le relais sera activé pendant le temps ON. A la fin du temps ON, le relais se désactivera durant le temps OFF. A la fin du 
temps OFF, le temps ON recommence à nouveau. 

2 – Cyclique par tension OFF / ON 

En connectant l’alimentation le relais sera activé pendant le temps OFF A la fin du temps OFF, le relais se 

désactivera durant le temps ON. A la fin du temps ON, le temps OFF recommence à nouveau. 

3 - Cyclique par bouton poussoir ON/OFF

En fermant le bouton START le relais sera activé durant le temps ON. A la fin du temps ON, le relais se désactivera durant le temps OFF. A la fin du 
temps OFF, le temps ON recommence à nouveau. 

4 - Cyclique par bouton poussoir OFF/ON

En fermant le bouton START le relais sera activé durant le temps OFF. . A la fin du temps OFF, le relais se désactivera durant le temps ON. A la fin 
du temps ON, le temps OFF recommence à nouveau.

5 - Temporisation avec Retard par tension (Équivalent I-33 et I-34)

En connectant l’alimentation la temporisation OFF commence mais sans connecter le relais. A la fin du temps OFF le relais est connecté durant le 
temps ON.