From 50 sec. Up to 30 min.

CYCLIC TIMER

I-111

TECHNICAL CHARACTERISTICS

Voltage. ........................................... 230 V. AC..

Medium Consumption. .................... 1 W.

Minimum Timing. ............................. 50 sec.

Maximum Timing. ........................... 30 min.

Maximum load at the relay. ............. 5 A.

Indicator timing Led. ........................ Yes.

The I-111 circuit is a cyclic timer at 230 V AC with relay output. The module will maintain activated the output according to an

operating time and a quiescent time, both adjustable between 0,3 sec. and 1 min. Operating-Quiescent cycle is permanently

done until you disconnect the power supply. It includes an indicator timing led, connector to place an exterior potentiometer

and terminals to connect it.

Be carreful. Don’t forget that there is 230 VAC in several parts of the circuit.

OPERATING

MODULE'S SUPPLYING : 

The Circuit I-111 had to be supplied by 230 VAC. Using an adequate plug and a cable for

mains connect this last one to the input terminal 230 VAC. Install a fuse and a switch as it is indicated in General Wiring

Map (see hereafter). Both are necessary to protect the module and for your own security, as it is indicated in EEC

regulations. Then, verify that you have correctly connected the module.

Before to connect the module to the mains inserting voltage, please do the rest of connections specified hereafter. Do not

forget that in several part of the module there is voltage (230 VAC), for this reason we suggest you to be carreful.

OPERATING-QUIESCENT CYCLE : 

The I-111 circuit has two times. Operating time (when the relay will be connected)

and quiescent time (when the relay will not be connected between two operating time).

To select operating and quiescent times you have to adjust potentiometers inserted in the P.C.B.

When the time is selected, press the push button to supply the module. The circuit I-111 will automatically connect the

output during the previously indicated operating time and the led will light. When the operating time will be finished, led and

output will be disconnected during the selected quiescent time. At the end of this quiescent time, the module I-110 will be

activated once again.

OUTPUT. CONNECTION OF THE LOAD 

The output Module (I-111) is controlled by a relay, allowing any load until

5 A. as maximum consumption. The relay has 3 output terminals the normally open at quiescent (NA), the normally closed at

quiescent (NC) and the common. The operating of this mechanism is the same as a switch with two (2) terminals NA and

common, if you wish that the output will be activated during the timer, or between the NC and the common, to obtain the

reverse operating. In the Output connection paragraph, you could appreciate the typical connection for a devices operating

at 12 VDC and to operate at 230 VAC. The installation is between the Common and NA, where the device or load that you

wish to control will be activated during the operating time. To obtain the inverse operating, substitute in the connection the

NA by

EXTERIOR INSTALLATION OF THE POTENTIOMETER : 

you wish to substitute the potentiometer inserted in the

P.C.B, you had to withdraw the soldering. Then, connect cables between jumpers indicated as “J1“and "J2" and new

potentiometers. These last potentiometers have to be lineal and offering 1M.