6 Adressierung

Spezieller LED-Konverter, mit integriertem 

Überwachungsbaustein für Einzelleuchtenüber-

wachung (Überwachung der Versorgungselek-

tronik und automatische Detektion fehlerhafter 

Versorgung des LED-Moduls) mit 20-stelligen 

Adressschaltern

6 Addressing

Special LED-Converter with integrated moni-

toring module for individual monitoring of lumi-

naries (monitoring of the supply and automatic 

detection of faulty supply of the LED-module) 

with 20 adresses

Adressschalter 1

address switch 1

Adressschalter 2

address switch 2

Leuchtenadresse

Luminaire address

0

0

Überwachung aus / Monitoring off

0

1

1

0

2

2

.....

.....

.....

1

0

10

1

1

11

1

2

12

.....

.....

.....

2

0

20

2

1

nicht zul. / not permissable

2

2

nicht zul. / not permissable

.....

.....

.....

2

9

nicht zul. / not permissable

7 Wartung / Instandhaltung

Halten Sie die für Instandhaltung, Wartung und 

Prüfung von elektrischen Betriebsmitteln geltenden 

Bestimmungen ein. 

Im Fall von Rücksendungen benötigen Sie von uns 

eine RMA - Nummer. Entnehmen Sie bitte weitere 

Infos hierzu unserer Internetseite www.ceag.de. 

Die Lichtquelle dieser Leuchte ist nicht ersetzbar; 

wenn die Lichtquelle ihr Lebensdauerende erreicht 

hat, ist die gesamte Leuchte zu ersetzen. 

8 Entsorgung / Recycling

Beachten Sie bei der Entsorgung defekter Geräte die 

gültigen Vorschriften für Recycling und Entsorgung. 

Kunststoffteile sind mit entsprechenden Symbolen 

gekennzeichnet. 

7 Servicing / Maintenance

Observe the relevant national regulations applying 

to the maintenance, servicing and checking of  

electrical apparatus. 

In case of returns you need a RMA - number from 

us. For further information see www.ceag.de!

The light source of this luminaire is not replaceable; 

when the light source reaches its end of life the 
whole luminaire shall be replaced.

8 Disposal / Recycling

When disposing of defective devices, comply with 

valid regulations for recycling and waste disposal. 

Plastic parts are marked with corresponding symbols. 

Summary of Contents for GuideLed SL 13011.1 CG-S

Page 1: ...und Betriebsanleitung Mounting and Operating Instructions Zielgruppe Elektrofachkraft Target group Skilled electricians Verwendungszweck Notbeleuchtung nicht für privaten Gebrauch Intended Application Emergency Lighting not suitable for private use ...

Page 2: ...S FOR A PARTICULAR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES In no event will Eaton be responsible to the purchaser or user in contract in tort including negligence strict liabil...

Page 3: ...1 0x1 1 CG S 6 5 2 SL 130x2 1 0x2 1 CG S 8 5 3 Zusatzgehäuse 9 6 Adressierung 10 7 Wartung Instandhaltung 10 8 Entsorgung Recycling 10 Contents 1 Conformity with standards 4 2 Brief description Scope of application 5 3 Installation Operation 5 4 Technical Data 5 5 Construction Dimensional drawings 6 5 1 SL 130x1 1 0x1 1 CG S 6 5 2 SL 130x2 1 0x2 1 CG S 8 5 3 Additional enclosure 9 6 Addressing 10 ...

Page 4: ...d and flawless condition Only genuine CEAG spare parts may be used for replacement and repair When working on the emergency luminaire the system must first be blocked battery operation must be interrupted and mains must be switched off The picture below shows the indication label on the emergency luminaire Prior to its initial operation the luminaire will have to be checked in line with the instru...

Page 5: ...uminaires GuideLED CG S are sui table for operation on CEAG emergency lighting systems acc to EN 50 172 DIN VDE 0100 718 and E DIN VDE 0108 100 The advanced swit ching and monitoring mode is only available in combination with CEAG CG S technology 3 Installation Operation For the mounting and operation of electrical apparatus the respective national safety regula tions as well as the general rules ...

Page 6: ... class SL 130x1 1 SL 130x2 1 II I Schutzart nach EN 60529 Protection category acc to EN 60529 IP41 Modulgehäuse für Deckeineinbau und bei seitlicher Leitungseinführung IP20 IP 41 Module housing for recessed mounting and cabling sidewise IP 20 Umgebungstemperatur Permissable ambient temperature 20 C 40 C Netzanschlussklemmen Terminals Steckklemme 3 x 2 x 2 5 mm2 max 6 A plug in terminal 3 x 2 x 2 5...

Page 7: ...tel 6 Set adress of the module chapter 6 5 Aufbau der Leuchte Maßbilder 5 1 GuideLed SL 130x1 1 0x1 1 CG S Deckeneinbauleuchte 5 Construction of the luminaire Dimensional Drawings 5 1 GuideLed SL 130x1 1 0x1 1 CG S Recessed ceiling mounting Richtige Ausrichtung zur Fluchtwegrichtung beachten SL 13011 1 Observe right orientation in direction of escape route SL 13011 1 Deckenausschnitt Ø 64 68 mm Ce...

Page 8: ...ächenausleuchtung Luminaire for open area illumination Leuchte für Fluchtwegausleuchtung Luminaire for escape route illumination 80 44 80 Modulgehäuse Erforderliche Höhe zum Einführen in die Zwischendecke ca 100 mm Module enclosure Needed height for introducing into the intermediate ceiling approx 100 mm ...

Page 9: ...n Kapitel 6 Set adress of the module chapter 6 Leitungseinführungen Mains cable connection Optionale Leitungseinfüh rungen IP20 optional cable entries IP20 Befestigungslöcher Fixing holes Richtige Ausrichtung zur Fluchtwegrichtung beachten SL 13012 1 Observe right orientation in direction of escape route SL 13012 1 LEDs sind ESD empfind lich LEDs are ESD sensitive Nicht in das Leuchtmittel schauen...

Page 10: ...optional erhältiches Zusatzgehäuse an der Decke befes tigen und elektrisch anschließen Drahtung in die Leuchte einführen und anschließen Leuch te mit den mitgelieferten Schrauben am Zusatz gehäuse befestigen Optional For more space for wiring and cable entry fix the optional available enclosure to the ceiling and connect it electrically Introduce wi ring into the luminaire and connect it Fix the l...

Page 11: ...standhaltung Halten Sie die für Instandhaltung Wartung und Prüfung von elektrischen Betriebsmitteln geltenden Bestimmungen ein Im Fall von Rücksendungen benötigen Sie von uns eine RMA Nummer Entnehmen Sie bitte weitere Infos hierzu unserer Internetseite www ceag de Die Lichtquelle dieser Leuchte ist nicht ersetzbar wenn die Lichtquelle ihr Lebensdauerende erreicht hat ist die gesamte Leuchte zu er...

Page 12: ...die richtige Lösung für jede Anwendung zu finden Dabei erwarten Entscheidungsträger mehr als lediglich innovative Produkte Unternehmen wen den sich an Eaton weil individuelle Unterstützung und der Erfolg unserer Kunden stets an erster Stelle stehen Für mehr Informationen besuchen Sie www eaton de Ihre Ansprechpartner finden Sie unter www ceag de At Eaton we re energized by the challenge of powerin...

Reviews: