ordinary lighting and flashlight lighting. The control sequence of the switch
button is: lighting 1 bright/lighting 1 flash/lighting 2 bright/off;
5. How to use wireless charging:
Place the mobile phone in a position marked with a wireless charging area on the
top of the device, and turn on the main power button and the USB button in turn;
V. Fault code display
project abbreviation
description
Er 01
DC OCP
DC output module (DC12V & cigarette lighter) and output over-
current
Er 02
DC SCP
DC output module (DC12v & cigarette lighter) and output short
circuit or wrongly inserted into charger
Er 03
AC Error
AC module fault
Er 04
PD Error
One way type-C1 or type-C2 interface failure
Er 05
PCBA OTP
PCBA temperature too high
Er 06
BAT UTP
Battery temperature too low
Er 07
USBA Error
USBA1 or USBA2 output fault
Er 08
Reserve
Reserve
Er 09
BAT OTP
Battery over-temperature alarm
Er 10
BAT OCP
Battery over-current; System overload
Er 11
BAT UVP
Battery under-voltage warning
Er 12
BAT LOW
Battery low voltage warning
Er 13
WP Error
Wireless power charging failure