CDVI SOLARMBD Installation Manual Download Page 4

4

cdvigroup.com

Input LED management

Green 

LED

Red

LED

Status

OFF

OFF

Off

OFF 

ON

red

ON

OFF

green

ON

ON

blue

1

2

OFF

OFF

26 bits

1

2

ON

OFF

30 bits

1

2

OFF

ON

44 bits

1

2

ON

ON

Non attribué

3

ON

Standard

Pulls up 12 V or 5 V

Open collector outputs:

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

1

2

3

4

ON

ON

ON

ON

1

2

3

4

ON

ON

ON

ON

1

2

3

4

ON

ON

ON

ON

1

2

3

4

ON

ON

ON

ON

1

2

3

4

ON

ON

ON

ON

1

2

3

4

ON

ON

ON

ON

OFF= 5 V

ON = 12 V

Card Swiped (DIP3 

= ON)

-  Badge recognized: the 

orange LED illumi-

nates and the buzzer 

activates for 150 milli-

seconds.

1

2

3

4

ON

ON

ON

ON

1

2

3

4

ON

ON

ON

ON

1

2

3

4

ON

ON

ON

ON

1

2

3

4

ON

ON

ON

ON

1

2

3

4

ON

ON

ON

ON

1

2

3

4

ON

ON

ON

ON

1

2

3

4

ON

ON

ON

ON

1

2

3

4

ON

ON

ON

ON

1

2

3

4

ON

ON

ON

ON

1

2

3

4

ON

ON

ON

ON

1

2

3

4

ON

ON

ON

ON

1

2

3

4

ON

ON

ON

ON

5] WIRING DIAGRAM 

DIPSWITCH 1 & 2 POSITIONING

DIPSWITCH 3 POSITIONING 

DIPSWITCH 4 POSITIONING 

WHEN READER FRONT PANEL CLOSED
Powered up the reader

- Green LED illuminates for 1 second.

- RED LED illuminates for 1 second.

- Buzzer sounds for 1 second.

- Orange LED illuminates (waiting confi guration).

- use the confi guration tag (Green LED blinks) >    

  waiting for user tag.

Operating mode

- Buzzer activated with 0V input.

- LEDs activated with 0V input.

C20

R19

C28

CR1

CR2

CR4

CR5

CR8

C5

5

C56

C57

C6

2

C63

C64

C65

C66

C67

C68

C69

C70

CR30

C73

C74

C75

CR6

C77

C78

C1

C2

C7

C8

C9

D2

D3

D6

1

L1

L2

L3

L4

L5

L8

R10

R11

R12

R13 R14

R15 R16

R17

R18

Q2

Q4

R28

Q5

R29

Q6

Q7

Q8

R30

R31

R3

3

R34

R35

R1

R3

6

R37

R3

R38

R4

R39

R5

R6

R7

R8

R9

R40

R46

R48

R49

R50

R51

R52

R53

R54

R55

R56

R57

R58

R59

R60

R61

R62

R63

R64

R65

R66

R67

R68

R69

R70

R71

R72

R73

R74

R75

R76

R77

R78

R80

C10

C13

C14

1

P3

C27

CR7

C76

CR9

CR28

CR20

CR27

CR21

CR29

CR19

I1

1

2

3

4

ON

ON

ON

ON

-

+

+

-

BZ3

P1

1

CR10

CR12

CR15

CR13

CR25

CR26

CR24

MM16

MM14

L7

MM3

MM10

CR11

CR3

MM1

MM15

C58

C6

+

-

R25

P2

C61

+

-

+

-

C24

C59

C25

CR22

WIRING

Red

Input voltage 12V dc

Black

0V

Blue

Clock

Green

Data 0

White

Data 1

Brown

Buzzer input

Yellow

Green LED input

Orange

Red LED input

WARNING : 

The confi guration is lost when power

is switched off or when tamper switch is released

EN

SOLARMWD - SOLARMBD

13.56Mhz EV1 Desfi re Mifare

®

 Reader - Wiegand

  INSTALLATION MANUAL

Summary of Contents for SOLARMBD

Page 1: ...The installer s choice cdvigroup com SOLARMWD SOLARMBD Lecteurs Mifare Des re EV1 13 56 Mhz Wiegand 13 56 Mhz EV1 Des re Mifare Readers Wiegand ENGLISH ENGLISH EN FRANCAIS FRANCAIS FR...

Page 2: ...ader controller INTBUSW These products must be powered in 12Vdc and the power supply should be certi ed EN60950 1 2006 A11 2009 standards and should be designed to be a low power supply source Recomme...

Page 3: ...e no pieces missing from the mounting kit Use the correct tools according to the installation drill screwdrivers tape measure and follow the mounting instructions of the reader 1 3 2 Sch a Sch b Sch c...

Page 4: ...luminates for 1 second Buzzer sounds for 1 second Orange LED illuminates waiting con guration use the con guration tag Green LED blinks waiting for user tag Operating mode Buzzer activated with 0V inp...

Page 5: ...erred from bit 7 to bit 0 2 Second parity 1 bit odd parity for the last 12 bit Bit 1 Bit 2 to bit 25 Bit 26 Even Parity on bit 2 to bit 13 Data 24 bit Odd Parity on bit 14 to bit 25 Exemple code of th...

Page 6: ...0 0001 0001 0110 1011 0110 1 Parity 1 0 0 6 6 A 3 7 Parity 2 The code transmitted is in hexadecimal format 0166A37 Parity 1 0 if the number of 1 in bit 2 to bit 15 is even 1 if the number of 1 in bit...

Page 7: ...EMENT ON CENTAUR SYSTEM GREEN LED SETTINGS RED LED SETTINGS GREEN ACCESS ALLOWED RED ACCESS DENIED BLUE STAND BY LED ACTUATION ACTUATION 9 NOTES EN SOLARMWD SOLARMBD 13 56Mhz EV1 Des re Mifare Reader...

Page 8: ...e le lecteur n est aliment ni par la centrale ni par le contr leur de porte INTBUSW Nos alimentations sont conforme aux exigences de la norme EN60950 1 2006 A11 2009 et construite pour tre une aliment...

Page 9: ...oir v ri que le kit de montage est complet vous allez pouvoir proc der l installation nale de votre lecteur R unissez le mat riel appropri Per euse tournevis m tre et suivez les recommandations de mon...

Page 10: ...eu Clock Vert Data 0 Blanc Data 1 Marron Entr e Buzzer Jaune Entr e voyant vert Orange Entr e voyant rouge Commande des voyants Voyant vert Voyant rouge Etat OFF OFF teint OFF ON rouge ON OFF vert ON...

Page 11: ...e mot est transmis bit de poids fort en premier 2 2nde parit 1 bit parit impaire des 12 derniers bits Bit 1 Bit 2 bit 25 Bit 26 Parit paire sur bit 2 bit 13 Donn e 24 bits Parit impaire sur bit 14 bit...

Page 12: ...0110 1 Parit 1 0 0 6 6 A 3 7 Parit 2 Le code mis est 0166A37 en hexad cimal Parit 1 0 si le nombre de 1 dans bit 2 bit 15 est pair 1 si le nombre de 1 dans bit 2 bit 15 est impair Parit 2 0 si le nom...

Page 13: ...YANTS SUR LE SYST ME CENTAUR PARAM TRAGE VOYANT VERT PARAM TRAGE VOYANT ROUGE VERT ACC S AUTORIS ROUGE ACC S REFUS BLEU EN ATTENTE TAT VOYANTS 9 NOTES FR SOLARMWD SOLARMBD Lecteurs Mifare Des re EV1 1...

Page 14: ...14 cdvigroup com FR SOLARMWD SOLARMBD Lecteurs Mifare Des re EV1 13 56 Mhz Wiegand INSTALLATION MANUAL...

Page 15: ...15 cdvigroup com FR SOLARMWD SOLARMBD Lecteurs Mifare Des re EV1 13 56 Mhz Wiegand INSTALLATION MANUAL...

Page 16: ...21 21 CDVI FRANCE EXPORT Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI AMERICAS CANADA USA Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX BELGIUM NETHERLAND LUXEMBOURG Phone 32 0 56 73 93...

Reviews: