If you omit to reprogram the Master code in the new length format then the default master code value 
will be modified a follow: 

 
Code length changed to 4-digit code then the master code 2345 

Code length changed to 6-digit code then the master code 012345 
 

 
Press # to exit from programming mode 2 beeps confirm that you went back to the reading mode.  

 

4 beeps indicate a data computing error. 

 
 

C.

 

Master code 

 

Enter the master code twice (for the first use the master code default value is 12345). The orange LED and 
two beeps sound to confirm entry in the programming mode. 

 
Press 

¿

3 then enter the 3, 4, 5, 6, 7 or 8-digit new master code. The LED lights off during 1 second and an 

audible beep will sound to indicate that the new master code has been accepted. 
 

NEVER SET A PROGRAMMED USER CODE AS A MASTER CODE!  

 

Press # to exit from programming mode 2 beeps confirm that you went back to the reading mode.  

 

 

D.

 

Pin codes 

 

Enter the master code twice (for the first use the master code default value is 12345). The orange LED and 

two beeps sound to confirm entry in the programming mode. 

 

Enter the user number (00 to 99). The LED lights off during 1 second and an audible beep sound. 
 

If the LED is green, enter the 3, 4, 5, 6, 7 or 8-digit Pin code. The LED lights off during 1 second and an au-
dible beep is emitted.  

 
The LED lights in orange to indicates that the new Pin code has been programmed 

 
If a pin code has already been programmed or is the same as the master code, then 4 beeps are emitted. 

 
Then the LED lights on in red (user code programmed), select another user code or delete the Pin code pro-

grammed for this user code. 
 
Press # to exit from programming mode. 2 beeps confirm that you went back to the reading mode.  

 
 

E.

 

 Delete or replace a Pin code 

 

Enter the master code twice (for the first use the master code default value is 12345). The orange LED and 

two beeps sound to confirm entry in the programming mode. 

 

Enter the user number to delete (00 to 99). The LED lights off during 1 second and an audible beep 
will sound. 

 

The red LED indicates that the user number is already programmed. 

Press 

¿

 twice. The LED lights on in green to indicate that the user number can reprogrammed 

again. 
 

Enter another user number and follow the same steps to delete a Pin code. 

 

Press # to exit from programming mode 2 beeps confirm that you went back to the reading mode.   
 

 

Summary of Contents for PROMI E

Page 1: ... A G R A M A M D I N S T R U C T I O N S PROMI E 100 Pin codes I PRESENTATION This device comes with a varistor The varistor must be connected to the strike terminal electromagnet operated by the device If this product works with many strikes each of them should have a varistor The varistor controls the overload produced by the strike coil emf If you are using a Shear Lock electromagnetic lock it ...

Page 2: ...r the key in time in seconds 10 for 10 seconds up to 99 for 99 seconds The LED lights off during 1 second and a beep will sound to confirm that the time has been accepted Press 1 then enter the door release time in seconds 01 for 1 second up to 99 for 99 seconds Enter 00 for a latched output The LED lights off for 1 second and a beep will sound to confirm that the time has been accepted Press to e...

Page 3: ...g mode Enter the user number 00 to 99 The LED lights off during 1 second and an audible beep sound If the LED is green enter the 3 4 5 6 7 or 8 digit Pin code The LED lights off during 1 second and an au dible beep is emitted The LED lights in orange to indicates that the new Pin code has been programmed If a pin code has already been programmed or is the same as the master code then 4 beeps are e...

Page 4: ... to reset all the memory The red LED flashes during 5 seconds then stops flashing and becomes solid red during the rest of the reset The LED lights off Remove the jumper to go back to the stand by mode VI WIRING DIAGRAM ST1 on Reset ST1 off stand by mode PROMI E description 12 Input voltage 12V AC DC V Input voltage 12V AC DC T N O contact C Common R N C contact M Common PB B Request to exit input...

Page 5: ...5 Do not forget to put the varistor on the lock User number Pin Codes User ...

Page 6: ...6 20 5 105 120 135 23 24 15 38 61 75 5 Wiring access Area 30 x 40 ...