Operate by a MASTER Tx
,
To operate by a Master Tx , you have to ADD Master at first :
- place the Master on the Lock till the BEEP (magnet detected)
- then press “A” Button for 4 seconds till BEEP to enter in ADD MENU (beep pause-beep-pause…)
- Press again the “A” Button to ADD the Master into the memory of the RF receiver (Long beep-
pause-beep-pause-beep-pause…).
- The receiver is enabled to add more TX (other Master, and more User) for 15 seconds timeout
(beep-pause-bip-pause…).
When there is at least one Master present into the memory of the Lock, than you can use that
Master to ADD other Master or USER into the memory of the receiver.
ADDING more TX
by an already registered Master Tx
:
- place the registered Master on the Lock till the BEEP (magnet detected )
- then press “A” Button for 4 seconds till BEEP to enter in ADD MENU (beep pause-beep-pause…)
- The receiver is enabled to add TX (other Master - max 3 total , and more User – max 10 total) for
15 seconds timeout (beep-pause-beep-pause…)
If you try to ADD an already registered TX : nothing will happen , no signaling.
If you try to add more Tx when memory is full, 3 beep will signal the error: beep-beep-beep.
DELETING USER
by Master Tx
:
- place the Master on the Lock till the BEEP (magnet detected)
- then press “B” Button for 4 seconds till the DOUBLE BEEP to enter in the DELETE MENU (beep-
beep-pause-beep-beep-pause…)
- Press the pushbutton of the USER Tx that you want to remove
- The receiver is enabled to REMOVE more USER TX for 15 seconds timeout (beep-beep-pause-
beep-beep-pause…)
DELETING_ALL (Factory Default) by Master Tx
:
- place the Master on the Lock till the BEEP (magnet detected )
- then press “B” Button for 4 seconds till the double BEEP to enter in DELETE MENU (beep-beep-
pause-beep-beep-pause…)
- Press again “B” Button to DELETE_ALL (clear all memory to Factory default)
OPERATE BY ON BOARD RECEIVER PUSHBUTTON
By the on board pushbutton you can ADD USER Tx (also with no Master Tx installed) ADD
MASTER Tx or USER Tx
- Press pushbutton till BEEP and release pushbutton immediately
- After 2 seconds it will BEEP again (beep-pause-beep-pause…)
- You can ADD TX (USER or MASTER) for 15 seconds timeout.